Electro-Voice NetMax N8000 owner manual Important Safety Instructions

Page 3

IMPORTANT SAFETY INSTRUCTIONS

The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage“ within the product’s enclosure that may be of sufficent magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral tri- angle is intended to alert the user to the presence of important operating and maintenance (ser- vicing) instructions in the literature accompanying the appliance.

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a dry cloth.

7.Do not block any ventilation openings. Install in accordance with the manufacture’s instructions.

8.Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or the grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.Only use attachments/accessories specified by the manufacturer.

12.Use only with the cart, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13.Unplug this apparatus during lightning storms or when unused for a long period of time.

14.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power- supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15.Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.

16.To completely disconnect this equipment from the AC Mains, disconnect the power supply cord plug from the AC receptacle.

17.The mains plug of the power supply cord shall remain readily operable.

Management of WEEE (waste electrical and electronic equipment) (applicable in Member States of the Euro- pean Union and other European countries with individual national policies on the management of WEEE) The symbol on the product or on its packaging indicates that this product may not be treated as regular household waste, but has to be disposed through returning it at a Telex dealer.

IMPORTANT SERVICE INSTRUCTIONS

CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

1.Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance.

2.Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains.

3.Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.

5.Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.Altering the circuitry without prior consent or advice is not legitimate.

7.Any work security regulations that are applicable at the locations where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.

8.All instructions concerning the handling of MOS-circuits have to be observed.

NOTE:

SAFETY COMPONENT (MUST BE REPLACED BY ORIGINAL PART)

NetMax N8000 System Controller

3

Owner’s manual

 

Image 3
Contents Page Network configuration Important Safety Instructions Onformity Description of the system IntroductionN8000 features Unpacking and warranty IRIS-Net Installation instructionBrowser Interface Signal / PEAK-LEDs Control Elements and Connections Front FaceplateNETWORK-LEDs USB Interface System STATUS-LEDsRear Panel Audio SLOTsNetwork Module Slot RS-232 Interfaces Ethernet InterfaceControl Port Mains Connector and Power SwitchPreparations Mounting Installation of expansion cardsSystem expansion with analog/digital inputs or outputs System expansion with a network moduleExpansion of the DSP performance of the system Interface description Can Interface Assignment of can plug RS-232 Interface USB connectionControl Inputs Control Outputs Audio Interfaces Analog audio connecting cableDigital audio connecting cable Example Network configuration IntroductionNetwork configuration Click on Start Control Panel Network Connection ConfigurationDouble click on Internet Protocol TCP/IP NetMax N8000 System Controller NetMax N8000 System Controller Appendix Application Example Installation in a multi-purpose hallTroubleshootings Ethernet principles Appendix Check Network Configuration of PCSubnet mask IP addressesAutomatic/Manual Allocation of IP Addresses CAN-Bus Principles Appendix System Examples Performance Specifications IP Address Table General Description and Features Specifications/Technische DatenInterfaces Processing Block Diagram/BlockschaltbildDimensions/Abmessungen Page Page Page Subject to change withou prior notice V1.2

NetMax N8000 specifications

The Electro-Voice NetMax N8000 is a powerful digital signal processor (DSP) that has been designed to meet the demands of contemporary audio applications in both live sound and permanent installations. Offering a comprehensive suite of features, the N8000 provides high-quality audio processing, versatile routing, and a user-friendly interface, making it an ideal choice for audio professionals.

One of the standout features of the N8000 is its robust processing power. Equipped with multiple DSP cores, it can handle complex audio tasks simultaneously, ensuring that sound engineers have the flexibility they need to create intricate audio setups. The device supports up to 64 inputs and 64 outputs in configurations that can be easily customized through its flexible digital patching system. This scalability makes it suitable for a wide range of applications, from small venues to large concert halls.

Another key characteristic of the N8000 is its extensive network capabilities. The device supports Ethernet connectivity through the AVB (Audio Video Bridging) protocol, allowing for seamless integration with other AVB-enabled products. This feature allows for low-latency audio transmission and ensures high-quality signal integrity over longer distances, ideal for complex audio installations.

The N8000 also includes a comprehensive suite of advanced processing algorithms. These include delay, equalization, crossover, and dynamics processing, all of which can be easily adjusted via the intuitive software interface. The Electro-Voice NexSys software allows users to create and save presets, making it easy to recall specific settings for different events or venues.

In terms of build quality, the N8000 boasts a rugged chassis that is designed to withstand the rigors of touring and installation environments. Its rear panel features a variety of input and output options, including analog and digital connections, providing flexibility for different system designs.

Furthermore, the N8000 is designed with expansion in mind. Its modular architecture allows for additional cards to be added, enhancing the system's capability over time. This means that as audio technology evolves, users can keep their system up-to-date without the need for a complete replacement.

In summary, the Electro-Voice NetMax N8000 is a versatile and powerful DSP solution that combines advanced processing capabilities, robust connectivity, and a user-friendly interface. Its ability to adapt to various audio environments makes it an indispensable tool for sound engineers and installers looking to create the best possible audio experience.