Directed Electronics A600/4, A1200/4 manual Power Wire Size

Page 13

load, double its 4 ohm RMS rating. These amplifiers will effectively double their power at this load.

1000W X 1.5 X2 = 3000 watts

3000W = 250 Amps total current draw

12V

If you are using more than one amplifier, add up the total current draw for all of them and choose the appropriate gauge based on the grand total.

POWER WIRE SIZE

A minimum of 8 gauge or a maximum of 4 gauge wire is recommended dependent on the application.

The ground wire must be the same gauge as the power wire.

12

Image 13
Contents Amplifier Models Table of Contents Congratulations ServiceCEA Specifications FeaturesWHAT’S Included General Specifications SpecificationsFuse Requirements Amplifier Status Leds TOOLS/PARTS for Installation Wiring Powerlocktm Ground Wiring Current Draw Charging SystemPower Wire Size Amplifier Bridging Power Lock ConnectorsMixed Mono Output A600/4 Front Plate Diagram Rear Speaker Connector Speaker PowerLockTM connectorPage A1200/4 Front Plate Diagram A600/4 END Plate DiagramPage A1200/4 END Plate Diagram Source Headunit InputsA600/4, A1200/4 Block Diagram Qbass Advanced Instrumentation InputQbass Plus QBASS/QBASS Plus SpecificationsOUT TC-X Crossover A600/4, A1200/4Crossover Detent Chart Input Combine Adjusting Input GainHigh Mass Internal Heatsink AP-IV Protection CircuitOpposite Channel Same Channel Limited TWO Year Consumer Warranty