Input signals
|
| |
One | Frequency range | |
frequency/pulse input | Minimum pulse width | 25 |
| Power | Sourcing or sinking |
| Voltage | |
|
| |
| Current | Nominal 5 mA |
Two discrete | Pulse width | 0.15 sec minimum |
momentary inputs | Voltage | |
|
| |
|
| Dry contacts |
Intrinsically safe input signals
One
Output signals
Non-intrinsically safe output signals
Two active
Three discrete outputs
One
Isolated to ±50 VDC from all other outputs and earth ground
Maximum load limit of 1000 Ohms
Output is linear with process from 3.8 to 20.5 mA per NAMUR NE43 (June 1994)
Configurable for the application |
|
Polarity | Active high or active low, software selectable |
Power | Internal |
Voltage | 24 VDC nominal |
Current | Sourcing at 5.6 mA when Vout = 3 VDC |
| Sinking up to 500 mA at 30 VDC maximum |
Scalable to 10,000 Hz
Output is linear with flow rate to 12,500 Hz
Pulse width | 50% duty cycle above the crossover frequency(1) | |
| Configurable between 0.543 ms and 277 ms | |
Polarity | Active high or active low, software selectable | |
Power | Active or passive, software selectable | |
Voltage | 24 | VDC nominal, active |
| 30 | VDC applied maximum, passive |
Current | Sourcing at 10 mA at 3 VDC, active | |
| Sinking at 500 mA, active or passive |
(1)The crossover frequency depends on the configured value of the pulse width. At the minimum pulse width value of 0.543 ms, the crossover frequency is 922 Hz. At the maximum pulse width value of 277 ms, the crossover frequency is 1.8 Hz.
6Micro Motion® Series 3000 Transmitters and Discrete Controllers