Emerson Series 3000 Model 3100 accessory, Model 3500/3700 liquid flow performance, Relays module

Page 10
Model 3100 accessory

Model 3100 accessory

Relays module

Three relays

 

Solid state, SPST

 

Rated at 24–250 VAC, 40 mA to 5 A; or 0–70 VDC, 5 A

 

Energized by discrete outputs

 

NEMA 4X (IP65) enclosure (optional)

UL and CSA approvals

Class I, Div. 2, Groups A, B, C, and D

ATEX approvals

Suitable for installation in Zone 2, when properly installed in a suitable enclosure, complying with

 

ATEX Directive (94/9/EC) for Group II, Category 3G, according to CENELEC standard EN 50021

 

(1998) and marked as:

 

EEx n V II T4

 

KEMA 97 ATEX4940X

 

Ambient temperature –20 to +60 °C (–4 to +140 °F)

 

Additional installation-specific requirements are described in detail in the Series 3000 instruction

 

manual.

 

 

Model 3500/3700 liquid flow performance

Mass flow accuracy(1)(2)

Volume flow accuracy(1) (2)

Repeatability(2)

Sensor model

 

ELITE®

±0.05% of rate

F-Series

±0.10% of rate

H-Series

±0.10% of rate

T-Series

±0.15% of rate

R-Series

±0.50% of rate

ELITE

±0.05% of rate

F-Series

±0.15% of rate

H-Series

±0.15% of rate

T-Series

±0.25% of rate

R-Series

±0.50% of rate

ELITE

±0.025% of rate

F-Series

±0.05% of rate

H-Series

±0.05% of rate

T-Series

±0.05% of rate

R-Series

±0.25% of rate

(1)Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis.

(2)For the details of flow accuracy and repeatability specifications, refer to the product data sheet for each sensor family.

10Micro Motion® Series 3000 Transmitters and Discrete Controllers

Image 10
Contents Large operator interface for easy setup & control Product Data SheetWide variety of applications 2400S Micro Motion transmitters and controllers1700 2500Contents Series 3000 transmitters and discrete controllersRack-mount HousingsApplications Panel-mountPower connection Interface/displayElectrical connections DisplayNon-intrinsicallysafe input signals Input signalsOutput signals Intrinsically safe input signalsFault indication Output signals continuedDigital communications AC power supply Environmental specificationsPower supply DC power supplyUL and CSA Hazardous area classificationsATEX Mass flow accuracy12 Volume flow accuracy1 Model 3100 accessoryModel 3500/3700 liquid flow performance Relays moduleModel 3500/3700 gas flow performance WeightModel 3500/3700 density performance liquid only Sensor modelDimensions in DimensionsRack-mountModel 3300/3500 inchesDimensions in Dimensions continuedinches inches Dimensions continuedDimensions in DIN-rail-mount screw terminals detailDimensions in inchesmm Field-mountModel 3350/3700Dimensions continued Conduit openings viewOrdering information - Model 2Available with Chinese M language option onlyCode Ordering information - Model 3300 continuedCode CodeModel Ordering information - Model2Available only with language option M Chinese Code Ordering information - Model 3350 continuedCode CodeSensor interface code 6 remote core processor Ordering information - Model2Available with Chinese M language option only Code Ordering information - Model 3500 continuedCode CodeSensor interface code 6 remote core processor Ordering information - ModelModel 2Available only with language option M ChineseCode Ordering information - Model 3700 continuedCode CodeModel 1 Not available with approval code BPage Page Page Product breadth Technology leadershipUnparalleled value