Electrolux WHWURAOOOO, WHXURAOOOO, WHXUSFOOOO, WHXUSAOOOO, WHXURFOOOO II . Installation Instructions

Page 6

INSTALLATION INSTRUCTIONS

II . INSTALLATION INSTRUCTIONS

1.

INSTALLATION

1.3

ASSEMBLING TWO APPLIANCES

The appliance is designed for connection to fixed lines. The appliances are suitable for setting up as single appliances or as a group of appliances. They can be set up freely in the room, side by side, at the side and/or at the back against a wall.

Gaps between two appliances or appliance and sidewall should be filled with a FDA approved silicone such as Samco RTV103.

1.1DISTANCES

If an appliance is set up next to or against temperature-sensi- tive furniture or similar, a safety gap of approximately 6“ (15

mm)should be maintained or some form of heat insulation fit-

ted.

The walls must be made up of non-combustible material like tiles or steel.

1.2HEIGHT ADJUSTMENT

Appliance on feet: Alignment is carried out by screwing the lower foot parts in or out.

Appliance on

Irregularities or differences in height can

steel plinth:

be equalized by inserting one or several

 

strips of chrome nickel steel.

Appliance on feet.

DTurn the lower part of the feed to adjust the appliance high.

The feet are adjustable from 4“ to 8“ (100 to 200 mm). A high of 8“ (200 mm) can be recommended and results in an appli- ance high of 35,4“ (900 mm).

Note:

Adjustment of the legs shall provide an unobstructed clearance of minimal 6“ (150 mm) and maximal 8“ (200

mm)beneath the unit due to sanitary and stability aspects.

(1)

(2)

a

(1)

(3)

(2)

b

The lower part of the foot must not be unscrewed too far. The exposure of threads is prohibited.

c

Fig.1 Lateral connection

The assembly kit contains three of each of the following:

caged nuts (1 / Fig.1) pre-assembled on the right-hand side of the appliance, hexagonal screws M8x25 (1 / Fig.1), bolts with retaining rings (2 / Fig.1) and mounting links (3 / Fig.1)

DRemove the control panels from both appliances as in 2.2

DRemove the front panels from both appliances as in 2.1

DInsert the bolts with the retaining rings (2 / Fig.1) from out- side into the guide in the right-hand connecting plate.

DKeeping the screw (3 / Fig.1) loose, turn it until it is approx- imately 5 mm deep in the caged nut.

Positioning the appliances:

DPlace the appliances next to one other.

DAlign for position and height.

Connect the appliances:

DPush the appliances together so that the bolts (1 / Fig.1) engage in the guides of the appliance to be attached.

DFit the mounting link (3 / Fig.1) into the inside of the second appliance's left connecting plate.

DTighten the screws.

Note

If required, the caged nuts can also be fitted on the other side of the appliance.

The connection of two appliances (Fig 1c, arrow) must corre- spond to the hygienic regulations respective the standard NSF/ANSI 4. All resulting joints and seams in a splash zone shall be sealed and smooth.

Page 4

62.9676.01_UL

Image 6
Contents Thermaline S90 Installation Drawings Plans Dinstallation Connections RaccordementGeneral Information Installation Instructions IIIOperating Instructions 62.9676.01UL General Information II . Installation Instructions Installation InstructionsInstallation Access to Interior Sidewall D Assembling on CastorsSteel Plinth Control Panel C DownpipeFront Panels a and B OVEN, Storage SPACE, HOT CabinetInstallation Instructions Electrical Connection Connection TerminalsConnection to the Potential Equalization System III . Operating Instructions Operating InstructionsGeneral Cleaning Storage SpaceMalfunction Operating Instructions Instructions Générales Mise EN Place II . Instructions Relatives À LinstallationInstructions Relatives À Linstallation Assemblage DE Deux AppareilsAccès À Lintérieur Paroi Laterale D Assemblage SUR RoulettesSocle EN Acier Panneau DE Commande C SortiePanneau Avant a et B Bornes DE Connexion Branchement AU Système ÉquipotentielIII . Instructions DE Fonctionnement Instructions DE FonctionnementGénéralités Problème Problème Cause SolutionEspace DE Rangement Nettoyage