Cooktop/Downdraft Vent
Countertop Preparation
Countertop Preparation for 30" & 36" Cooktop / Downdraft Vent Installation
For detailed cooktop and downdraft vent installation specifications, refer to
Top
23 1/4"
min.
25"
Vertical noncombustible surface - rear wall
B |
C |
Flush with |
back side of |
cabinet front |
A |
|
|
|
|
| Backsplash | |||||
|
|
|
|
| 3/4" max. | |||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 2 9/16" | |||
|
|
|
|
|
| |||||
D* |
|
|
| 1/4" min. | ||||||
E** | ||||||||||
|
| flat ledge | ||||||||
|
|
|
|
|
*Overall flat ledge behind backside of cabinet front
**Minimum flat surface
required to fit top surface of cooktop and downdraft vent cap
E30DD75ESS / 30" Cooktop Cutout Dimensions
30" Cooktops | A | B | C | D | E |
EW30IC60I | 30" | 27 3/4" | 20 1/2" | 23 5/16" | 24 5/16" |
EW30CC55G | 30" | 27 3/4" | 20 1/2" | 23 5/16" | 24 5/16" |
EW30EC55G | 30" | 27 3/4" | 20 5/8" | 23 7/16" | 24 7/16" |
EW30GC55G | 28 1/2" | 27 3/4" | 19 3/4" | 22 9/16" | 23 9/16" |
EW30GC60I | 28 1/2" | 27 3/4" | 19 3/4" | 22 9/16" | 23 9/16" |
Countertop |
| 25" (standard countertop)* | ||
3/4" max. backsplash thickness |
| |||
backsplash |
| |||
| 1/4" min. flat ledge |
| ||
| 213/16" | Downdraft | Countertop | |
Studwall | 2 1/8" | chimney top | raised lip | |
|
|
| ||
3" | 9/32" | Cooktop | ||
| ||||
115/16" |
| Vent unit |
| |
|
| Back side of | ||
| 213/16" |
| ||
Stiffener |
| cabinet front | ||
Vertical noncombustible surface - rear wall | ||||
| ||||
|
| 23 1/4" min. |
|
E36DD75ESS / 36" Cooktop Cutout Dimensions
36" Cooktops | A | B | C | D | E |
EW36IC60I | 36 1/4" | 33 3/4" | 20 1/2" | 23 5/16" | 24 5/16" |
EW36CC55G | 36 1/4" | 33 3/4" | 20 1/2" | 23 5/16" | 24 5/16" |
EW36EC55G | 36" | 33 3/4" | 20 5/8" | 23 7/16" | 24 7/16" |
EW36GC55G | 34 1/4" | 33 3/4" | 19 3/4" | 22 9/16" | 23 9/16" |
Cooktop Installation Note:
To ensure proper installation, refer to
Countertop Preparation Note:
Be aware of areas of potential interference called out in illustration. Countertop with raised lip and/or backsplash may not allow enough flat area for proper installation,
*Standard 25" countertop depth may NOT be adequate for some cooktop / vent installations, especially with backsplash.
Cooktop/Downdraft Vent
Countertop Preparation Specifications
•For detailed Cooktop installation, refer to
•Position cooktop/vent cutout so all required minimum clearances are met.
•Minimum flat countertop area must meet or exceed combined overall width and depth as shown. Standard 25" countertop depth may NOT be adequate for some cooktop/vent installations, especially with backsplash.
•Separate circuits required for cooktop and vent. (Refer to
•Always consult local and national electric and gas codes. Check local building codes for installation requirements, as they may vary per locale.
Downdraft Vent Specifications
•For detailed Downdraft Vent installations, refer to
•Voltage Rating – 120V/ 60Hz/15 Amps
•Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having
•Amps @120 Volts = 8.0 Amps
•Vent unit outside of building only.
•Vent must be installed in vertical orientation only.
•1,600 CFM remote exhaust blower (PN#5304444802) included with vent – shipped in separate box.
•Do not use flexible duct. Round duct instead of rectangular duct recommended, especially when elbows are required.
•When multiple elbows are necessary, ensure a minimum of 24" of straight duct between any two elbows.
•Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold.
•For most efficient airflow exhaust, use a straight run or as few elbows as possible.
•Cold weather installations should have additional backdraft damper installed.
•Installing a Downdraft Vent in combination with any gas cooking surface will affect optimum burner efficiency.
Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.com for detailed instructions.
Electrolux Major Appliances, N.A.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • | High standards of quality at Electrolux Home Products, Inc. mean | |
we are constantly working to improve our products. We reserve the right | ||
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • | ||
to change specifications or discontinue models without notice. |
DIC_DDV_PREP EL 10/10 | © 2010 Electrolux Home Products, Inc. | Printed in the U.S.A. |