CONTENTS
| page |
Technical Data | 2 |
Safety Requirements | 3 |
Provision for Ventilation | 3 |
Location of Appliance | 4 |
Installation | 5 |
Testing | 8 |
TECHNICAL DATA
DIMENSIONS
| Height | Width | Depth |
Height to hotplate | 900mm (nominal) | 600mm (nominal) | 600mm |
|
|
| (to front of |
|
|
| door panel) |
Space for fixing at hotplate level | 2mm minimum clearance |
|
|
Space for fixing above hotplate level | |||
Minimum space above hotplate | 787mm (If a cooker hood is fitted refer to the cooker hood | ||
| installation instructions). |
|
|
Weight of appliance | 64.5kg. |
|
|
Minimum distance from rear wall | 5mm (spacer given by pressed spacer on vent panel). |
CONNECTIONS
Gas | Rear left hand side of cooker at hotplate level. |
| Rc½ (½" B.S.P. female). |
Electric | 230V 50 Hz mains 3 core cable is supplied with an integral, |
| moulded plug fitted with a 13 amp fuse. |
IGNITION
Spark generator | APCO 5MG 16913 |
|
| |
GRILL | L.P.Gas |
|
|
|
Heat Input | 3.0kW (215 g/h) |
|
|
|
Injector Marking | 088 |
|
|
|
Injector Size | 0.88mm |
|
|
|
Cone Height | Not applicable as flame burns on surface of gauze | |||
HOTPLATE |
| L.P.Gas |
|
|
| R.H.F. | R.H.R. | L.H.R. | L.H.F |
Heat Input | 1.0kW | 2.0kW | 2.0kW | 2.7kW |
| (71.85 g/h) | (143.7 g/h) | ( 143.7 g/h) | (194 g/h) |
Injector Marking | 051 | 072 | 072 | 083 |
Injector Size | 0.51mm | 0.72mm | 0.72mm | 0.83mm |
Cone Length | 10mm | 15mm | 15mm | 15mm |