If the wiring is extended or a completely new cable fitted a 3-pin 13 amp plug should be fitted. (See Fig.4a).

Connect the wires as follows:

GREEN AND

 

BROWN to the Live Terminal.

 

YELLOW

 

BLUE to the Neutral Terminal.

 

 

 

GREEN and YELLOW to the Earth Terminal.

 

 

As the colours of the wires in the mains lead which you

 

 

fit may not correspond with the coloured markings

 

13 AMP

identifying the terminals in your plug, proceed as follows:

 

 

The wire which is GREEN and YELLOW must be

 

 

connected to the terminal in the plug which is marked

 

 

with the letter 'E' or by the earth symbol

 

 

 

 

 

or coloured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GREEN or GREEN and YELLOW.

 

 

The wire which is coloured BLUE must be connected to

BLUE

 

the terminal which is marked with the letter 'N' or

BROWN

coloured BLACK.

Fig.4a

 

The wire which is coloured BROWN must be connected

 

to the terminal which is marked with the letter 'L' or

 

 

coloured RED.

 

 

FIT A 13 AMP FUSE TO THE PLUG HOLDER.

 

 

Ensure that the supply cable cannot get caught by the stability bracket. Plug in the appliance.

6. PRESSURE TESTING

1The hotplate rapid burner injector is used as a pressure test point.

2Lift the lid and connect the pressure gauge to the rapid burner injector.

3Check the supply pressure by turning rapid burner tap on full and one other hotplate tap full on and light the appropriate burner. The pressure must be set to 28mbar for use on butane or 37mbar for use on propane.

4.Turn off the taps and disconnect the pressure gauge.

7.CHECKING THE GRILL

Place the grill pan containing the trivet into the grill compartment. To light the grill burner , turn the grill tap to its full on position, then press the ignition button until the burner is lit.

8. CHECKING THE HOTPLATE

Lift the lid. Fit the burner crowns and caps ensuring that they are correctly seated. Fit the pan supports. Check each of the hotplate burners in turn by turning the hotplate tap to it's full on position then pressing the ignition button until the burners are lit.

9.CHECKING LID SHUT-OFF DEVICE

1.Lift the lid.

2.Turn one hotplate burner tap to its full on position, then push and release the ignition button.

3.Close lid. There should now be no gas supply to the hotplate and the burner will go out.

4.Turn off the hotplate tap and lift the lid. The gas supply should now be restored to the hotplate, when the tap is turned on.

8

Image 44
Contents Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Dual Fuel Cooker Leave These Instructions with the UserContents DimensionsConnections IgnitionImportant Safety Requirements Main OvenGeneral Provision for VentilationLocation of Appliance Parts Required Levelling the ApplianceFitting the Stability Bracket Connecting to GAS Connection to the Electricity SupplyPressure Testing Checking the GrillChecking the Hotplate Checking LID SHUT-OFF DeviceChecking the Main Oven Controls Checking the Main OvenAutomatic Operation Checking the Main Oven LightPage Page Parkinson Cowan