Wiring Diagram
L
1
A | 0 | 2 |
3
220/240 4
5
6
B
N
A. IGNITOR SWITCH
B. IGNITOR UNIT
Fault Finding
Preliminary Electrical Systems Check
PLUG (with cover | SOCKET |
removed) | (face view) |
Brown Blue
Blue
Brown Green Yellow
| Earth Wire | ( | ) | ) |
| Green/Yellow |
| E ( | |
|
|
|
| |
START |
|
| FUSE |
|
Isolate appliance | Neutral Wire |
|
| |
and carry out: | Blue |
|
|
|
A: Earth Continuity |
|
| N | L |
check. |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
NO | YES | Carry out: |
| Carry out: |
| Electricity supply | ||
|
|
| C: Polarity check. |
| D: Resistance to |
|
| should now be |
|
|
|
|
|
| |||
|
|
|
| Earth check. |
| satisfactory. | ||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Has inlet fuse blown?
NO | YES |
Inlet wiring faulty. Rectify any fault.
Isolate appliance and carry out:
B:Insulation check. Rectify any fault including replacing fuses as necessary.
A. EARTH CONTINUITY CHECK
a)Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 Ω (Ohm), check all earth wires for continuity and all contacts are clean and tight.
B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.
a)meter set on Ω (Ohms) x 1 scale.
Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.
b)meter set on Ω (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads less than ∞ (infinity) there is a fault.
NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.
It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.
13