Electrolux EHG 7763 Wiring Diagram, Fault Finding, Preliminary Electrical Systems Check, Yes

Page 13

Wiring Diagram

L

1

A

0

2

3

220/240 4

5

6

B

N

A. IGNITOR SWITCH

B. IGNITOR UNIT

Fault Finding

Preliminary Electrical Systems Check

PLUG (with cover

SOCKET

removed)

(face view)

Brown Blue

Blue

Brown Green Yellow

 

Earth Wire

(

)

)

 

Green/Yellow

 

E (

 

 

 

 

START

 

 

FUSE

 

Isolate appliance

Neutral Wire

 

 

and carry out:

Blue

 

 

 

A: Earth Continuity

 

 

N

L

check.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

YES

Carry out:

 

Carry out:

 

Electricity supply

 

 

 

C: Polarity check.

 

D: Resistance to

 

 

should now be

 

 

 

 

 

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring faulty. Rectify any fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK -Appliance must be electrically disconnected - meter set on (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 (Ohm), check all earth wires for continuity and all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

13

Image 13
Contents Instruction Booklet Important Safety Information Description of the Hob ContentsHob burners OperationBurner Minimum Maximum Diameter Burner cap Burner crown Ignition electrode ThermocoupleHob Top Maintenance and CleaningBurners Ignition electrodeSomething Not Working? Symptom SolutionCast Iron Pan Supports Guarantee Conditions Engineers technical data Instructions for the InstallerProvision for ventilation Important safety requirementsLocation When the HOB is First Installed InstallationGas Connection Cut Out SizeBuilding over a cupboard or drawer BuildingBuilding over a kitchen unit with door Fitting the Hob into the worktopElectrical connections Supply cable replacementThis HOB Must be Earthed Permanent ConnectionFault Finding Wiring DiagramIgnitor Switch Ignitor Unit Preliminary Electrical Systems CheckIgnition System / Gas Ignition Page Customer Care