Important safety requirements

This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).

For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S. 813 Current Editions and the ETCI Rules for Electrical Installations.

Provision for Ventilation

Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.

The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required.

However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3.

If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements.

For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I.S. 813 Current Editions Table Four.

Location

The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room.

Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm between the rear edge of the hob and the wall.

A minimum distance of 100 mm must be left between the side edges of the hob and any adjacent cabinets or walls.

The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 420 mm If it is fitted below 420 mm a space of 50 mm must be allowed from the edges of the hob.

The minimum distance combustible material can be fitted directly above the hob is 700 mm.

For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S 813 Current Edition Section 7- Permitted Locations of Appliance.

14

Image 14 Contents
61502 G Child Safety Important Safety InformationInstallation During UseService Environmental InformationContents Description of the Hob 7 6Operation Hob burners control knobsBurner Minimum Maximum Diameter Pan Supports Maintenance and CleaningHob Top BurnersSymptom Solution Something Not Working? 0870 5 929 Service and Spare Parts Customer Care European Guarantee Guarantee ConditionsStandard guarantee conditions ExclusionsInstructions for the Installer Engineer technical dataType of GAS Important safety requirements LocationInstallation Gas Connection Building over a cupboard or drawer Cut Out SizeBuilding Building over a kitchen unit with door Seal Fitting the hob to the worktopElectrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningConversion from Natural Gas to LPG MethodPage AEG Hausgeräte GmbH Postfach 90327 Nürnberg Electrolux plc