Electrolux 1554-6 iU installation instructions Fitting the plinth, Power supply, 220, ~50 Hz

Page 13

Fitting the plinth

Important!

For the efficient operation of the appliance, it is important that the original ventilation grid is used.

For an opening height dimension A=820 mm and a plinth height dimension a=100 mm, the plinth may be fitted without adjustments. The same applies to an opening height dimension B=870 mm and a plinth height dimension b=150 mm.

For plinth heights greater than a=100 mm, b=150 mm, a cut should be made in the plinth, 580 mm wide, in the centre of the appliance position, leaving a remaining height of a=100 mm, b=150 mm.

B = 870

A = 820

25

a = 100 b = 150

580

25 80

• Attach plinth to the kitchen units.

Important!

The plinth must be positioned at a minimun distance of 25 mm from the door.

Please check whether, after installing your appliance and especially after reversing the door, the door seal seals right round. A badly fitting door seal may lead to heavy frosting and result in a higher power con- sumption (see also “What to do if ...”).

Power supply

A correctly installed, earthed socket is required for the electrical supply. The supply must have a fuse rating of at least 10 Amps. If the socket is not accessible once the appliance is built in, the electrical installation must include suitable means of isolating the appliance from the mains (e.g. a fused spur).

Before initial start-up, refer to the appliance rating plate to ascertain if supply voltage and current values correspond with those of the mains at the installation location.

e.g.: AC 220

... 240

V 50 Hz or

220

... 240

V ~50 Hz

(i.e. 220 to 240 volts alternating current, 50 Hertz) The rating plate is inside the appliance on the left.

13

Image 13
Contents ÖKO-SANTO 1554-6 iU Dear customer Contents Safety of children Important Safety InstructionsPrior to initial start-up RefrigerantCase of malfunction Daily OperationRemove transport packaging DisposalAppliance Packaging Information Disposal of old AppliancesInstallation Location InstallationLeft door opening Reversing the doorUntil they click Page Adjust height Remove covering and adjust the bracket locking nuts Building the appliance in under a worktop Mounting furniture door Screw appliance into place Place the covering strip Fitting the plinth Power supply220 ~50 HzThis appliance may not correspond with Electrical ConnectionPrior to Initial Start-Up Description of the applianceView of the appliance Setting 0 means Off Starting up and temperature regulationSetting 1 means Hightest temperature, warmest set- tingStorage shelves/wire trays Interior AccessoriesCorrect storage Vario glass storage shelfCleaning and Care Switching off the applianceDefrosting Fridge defrosts automaticallyEnergy Saving Tips After everything is dry place appliance back into serviceWhat to do if Symptom Possible Cause RemedyCorrecting Malfunctions Turn the thermostat knob to a colder setting tem- porarily Changing the light bulb Service & Spare PartsHelp us to Help You 08705Noises during Operation Customer CareRegulations, Standards, Guidelines