4 MOUNTING AND WIRING
CONTINUED FROM PAGE 3
O/B/Y2*
Y1G
Compressor
Contactor
Stage 2
E/W1
W2
Heat
Relay
Stage 1
THERMOSTAT
C* R
SYSTEM
Hot
24 VAC | 120 VAC |
Compressor |
| Fan |
| Heat |
Contactor |
|
| Relay | |
| Relay |
| ||
Stage 1 |
|
| Stage 2 | |
|
|
|
Neutral
TRANSFORMER
(Class II, Current Limited)
*O/B Switch must be in “O” position
Figure 5. Typical wiring diagram for single transformer multi-stage systems
Multi-stage Terminal Outputs
Refer to equipment manufacturers’ instructions for specific sys- tem wiring information.
You can configure the thermostat for use with either
This thermostat is designed to operate a
transformer. If transformer safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75VA Class II transformer. After disconnecting one transformer, the two commons must be jumpered together.
Use the terminal output information below to help you wire the thermostat properly for your
THERMOSTAT TERMINALS
SYSTEM | L | C | R | W2 | E/W1 | (O/B)Y2* | Y1 | G |
|
|
|
|
|
|
|
|
|
Malfunction | 24 Volt | 24 Volt | Heat mode | Heat mode | Cool Mode | Cool mode | Blower/Fan Energized | |
| Light | (Common) | (Hot) | 2nd stage | 1st stage | 2nd stage | 1st stage | on call for Cool (and |
|
|
|
|
|
|
|
| Heat if configured |
|
|
|
|
|
|
|
| to Electric Heat) |
|
|
|
|
|
|
|
|
|
*O/B switch must be in “O” position |
|
|
|
|
|
|
Heat Pump Terminal Outputs
Refer to equipment manufacturers’ instructions for specific sys- tem wiring informtion.
You can configure the thermostat for use with the following heat pump system types:
HEAT PUMP TYPE 1.
This thermostat is designed to operate a
transformer. If transformer safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75VA Class II transformer. After disconnecting one transformer, the two commons must be jumpered together.
Use the terminal output information below to help you wire the thermostat properly for your
THERMOSTAT TERMINALS
SYSTEML
C
R
W2
E/W1
(O/B)Y2
Y1
G
Heat Pump 1 Malfunction Light
24 Volt | 24 Volt |
(Common) | (Hot) |
|
|
Heat mode 2nd stage (Aux.)
Emergency
Mode
Heat
B:Energized in Heat, Off, Emergency Mode
O:Energized in Cool Mode
Heat and | Blower/Fan Energized |
Cool mode | on call for Heat |
1st stage | and Cool |
(compressor)