Emerson 1F73 Multi-stage Terminal Outputs, Heat Pump Terminal Outputs, Thermostat System

Page 4

4 MOUNTING AND WIRING

CONTINUED FROM PAGE 3

O/B/Y2*

Y1G

Compressor

Contactor

Stage 2

E/W1

W2

Heat

Relay

Stage 1

THERMOSTAT

C* R

SYSTEM

Hot

24 VAC

120 VAC

Compressor

 

Fan

 

Heat

Contactor

 

 

Relay

 

Relay

 

Stage 1

 

 

Stage 2

 

 

 

Neutral

TRANSFORMER

(Class II, Current Limited)

*O/B Switch must be in “O” position

Figure 5. Typical wiring diagram for single transformer multi-stage systems

Multi-stage Terminal Outputs

Refer to equipment manufacturers’ instructions for specific sys- tem wiring information.

You can configure the thermostat for use with either multi-stage electric heat systems or multi-stage gas systems. When config- ured for electric heat, the G terminal (blower/fan) will be ener- gized on a call for heat.

This thermostat is designed to operate a single-transformer system. If you have a two-transformer system, cut and tape of one

transformer. If transformer safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75VA Class II transformer. After disconnecting one transformer, the two commons must be jumpered together.

Use the terminal output information below to help you wire the thermostat properly for your multi-stage system. After wiring, see CONFIGURATION section for proper thermostat configuration.

THERMOSTAT TERMINALS

SYSTEM

L

C

R

W2

E/W1

(O/B)Y2*

Y1

G

 

 

 

 

 

 

 

 

 

Multi-Stage

Malfunction

24 Volt

24 Volt

Heat mode

Heat mode

Cool Mode

Cool mode

Blower/Fan Energized

 

Light

(Common)

(Hot)

2nd stage

1st stage

2nd stage

1st stage

on call for Cool (and

 

 

 

 

 

 

 

 

Heat if configured

 

 

 

 

 

 

 

 

to Electric Heat)

 

 

 

 

 

 

 

 

 

*O/B switch must be in “O” position

 

 

 

 

 

 

Heat Pump Terminal Outputs

Refer to equipment manufacturers’ instructions for specific sys- tem wiring informtion.

You can configure the thermostat for use with the following heat pump system types:

HEAT PUMP TYPE 1. Single-stage compressor system; gas or electric backup.

This thermostat is designed to operate a single-transformer system. If you have a two-transformer system, cut and tape of one

transformer. If transformer safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75VA Class II transformer. After disconnecting one transformer, the two commons must be jumpered together.

Use the terminal output information below to help you wire the thermostat properly for your multi-stage system. After wiring, see CONFIGURATION section for proper thermostat configuration.

THERMOSTAT TERMINALS

SYSTEML

C

R

W2

E/W1

(O/B)Y2

Y1

G

Single-stage compressor system; gas or electric backup

Heat Pump 1 Malfunction Light

24 Volt

24 Volt

(Common)

(Hot)

 

 

Heat mode 2nd stage (Aux.)

Emergency

Mode

Heat

B:Energized in Heat, Off, Emergency Mode

O:Energized in Cool Mode

Heat and

Blower/Fan Energized

Cool mode

on call for Heat

1st stage

and Cool

(compressor)

www.white-rodgers.com

Image 4
Contents Contents Your Thermostat ReplacesPreparations Thermostat DetailsMounting and Wiring Electric/Gas Switch Fan OptionTerminal Switch Selection Attach Thermostat Base to WallTape OFF Fan Emergency Relay Compressor Aux Contactor StageHeat Pump Terminal Outputs Multi-stage Terminal OutputsThermostat System Check Thermostat Operation Specifications Configuration MenuConfiguration Menu OperationTroubleshooting Symptom Possible Cause Corrective ActionThermostat Setting and Thermostat To the Temperature Up KeyTo the Temperature Down Key Thermometer Disagree