Emerson 16E09-101 specifications Installation, Circuit Board Inside Cover, SW1

Page 2

INSTALLATION

To prevent electrical shock and/or equipment dam- age, disconnect electric power to system at main fuse or circuit breaker box prior to installation or service.

Where failure of this control may result in personal injury and/or property damage, additional alarms or limit controls must be installed.

This control is a temperature control and is not to be used as a temperature limit control.

Fig. 1 Control Front View and Description

The control has a user selection for changing the setpoint to be either the Cut In or the Cut Out setting. The user must be careful to understand how this effects the “range” in which the control will operate when the differential value is entered. If entered values are incorrect, the control could operate outside the user’s intended settings due to set-up error. See section titled "Operation".

Circuit Board

Inside Cover

TEMPERATURE UNITS INDICATOR (°F or °C)

ACTUAL TEMPERTURE

AT TEMPERATURE SENSOR

BINARY INPUT INDICATOR LIT WHEN UNIT IS IN “SETBACK” MODE REFER TO PAGE 6

MENU BUTTON

PRESS TO ENTER MENU MODE REFER TO PAGES 4 & 5

SETPOINT TEMPERATURE

HEATING MODE INDICATOR ( )

COOLING MODE INDICATOR ()

STATUS INDICATOR LED

LIT WHEN CONTROLLED LOAD IS ENERGIZED (ON).

(SEE NOTE)

TEMPERATURE “UP” BUTTON

TEMPERATURE “DOWN” BUTTON

SW1

COOL HEAT

SW1

COOL HEAT

Switch SW1 must be set for system mode as shown:

 

SW1

 

 

Refrigeration

Cool

 

 

Heating

Heat

 

 

NOTE:

Green Status Indicator LED and display backlight operation

It may be observed from time to time that the green status indicator LED and display back-light will briefly turn off during a call for heating or cooling. During this time, the control is performing a self-check lasting up to 15 seconds. This is normal operation of the control and the load power will be maintained

Fig. 2 Control Dimensions and Mounting Information

LEFT SIDE VIEW

FRONT VIEW

RIGHT SIDE VIEW

REAR VIEW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.58”

2.91”

6.73”

4.19”

5.59”

5.59”

.85”

2.8”

.85”

 

 

1.54”

 

 

2.54”

.76”

BOTTOM VIEW

2

Image 2
Contents Precautions DescriptionCircuit Board Inside Cover InstallationGreen Status Indicator LED and display backlight operation SW1Wiring SW2User Menu User Menu Operation SettingsOptions Menu Factory Press Comments Description Default Operation COOL/REFRIGERATIONLock Panel LP PTC Temperature Versus Resistance Tables SpecificationsNTC Temperature Versus Resistance Tables NTCTroubleshooting Problemas DE Solución Especificaciones Alarma de salida de combinado Uso FuncionamientoMás Referencia de Usuario DEL FuncionamientoUsuario DEL Menú Diferencial De operativo Temperatura RangoCalor Frontal panel delOff u On Teclado Bloquear 12 a Frío Corto ciclo-anti Demora ASdEléctricas Conexiones Instalación 6857G-37 Pieza DE N Opcionales servicio de Accesorios/Elementos 10-16E09

16E09-101 specifications

The Emerson 16E09-101 is a cutting-edge electronic controller designed specifically for heating, ventilation, and air conditioning (HVAC) systems. This controller stands out due to its advanced features, technologies, and characteristics that facilitate enhanced control and efficiency in managing climate conditions in both residential and commercial environments.

One of the main features of the 16E09-101 is its ability to support multiple HVAC components, including heat pumps, air conditioners, and ventilation systems. This versatility makes it suitable for a variety of applications. The controller is equipped with a user-friendly interface, which simplifies the setup process and allows users to monitor and adjust settings easily. The graphical display presents real-time data, including temperature, humidity, and system status, enabling quick diagnosis and troubleshooting of issues.

The Emerson 16E09-101 incorporates sophisticated control algorithms that optimize system performance while minimizing energy consumption. By utilizing advanced predictive logic, the controller can make adjustments to the operation of HVAC units based on real-time data inputs. This not only increases energy efficiency but also prolongs the lifespan of the equipment, offering cost savings over time.

Another key characteristic of the 16E09-101 is its built-in communication capabilities, which facilitate integration with building management systems (BMS). This feature enables centralized control and monitoring, allowing facility managers to oversee multiple units from a single interface. Additionally, its compatibility with various communication protocols ensures that it can easily connect to existing systems, further enhancing its utility.

The controller also supports a range of sensors, including temperature, humidity, and CO2 sensors, allowing for comprehensive monitoring of indoor air quality. This is particularly important in modern buildings where energy conservation must be balanced with occupant comfort.

In summary, the Emerson 16E09-101 is a highly capable and versatile electronic controller ideal for managing HVAC systems efficiently. With its advanced features, proactive control technologies, and robust communication capabilities, it offers significant benefits in terms of energy efficiency, system longevity, and user convenience. Whether for residential or commercial applications, the 16E09-101 exemplifies Emerson's commitment to innovation and quality in HVAC control solutions.