Wolf Pro Wall installation instructions T E R N a L B L O W E R W I R I N G, P O Rta N T N Ot E

Page 12

W O L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S

I N S TA L L WIRING

I N T E R N A L B L O W E R W I R I N G

I M P O RTA N T N OT E

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

Risk of electrical shock. This ventilation hood must be properly grounded. This unit should be installed by a qualified electrician in accordance with all applica- ble national and local electrical codes and standards.

When making electrical connections, make sure the electrical power is turned off at the power source or circuit breaker before proceeding.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on acciden- tally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Do not remove the control knob bezel to access hood wiring; this will damage the bezel assembly.

Remove the hood electrical box cover.

Run power cable to the installation location. Insert the power cable into the electrical box by running it through the wire clamp previously installed. Tighten the wire clamp to secure the cable. Refer to the illustration below for the location of the electrical box.

Risk of electrical shock. Do not remove the wire connector on the ORANGE wire from the hood.

Using the supplied wire connectors, connect wires as follows: BLACK wire from hood to power supply BLACK wire, WHITE wire from hood to power supply WHITE wire and GREEN or BARE wire from power supply to GREEN ground screw in the electrical box.

Place all wiring connections inside the electrical box and reinstall the cover. Make sure that the wires are secure and that no wires are pinched between the cover and box.

Location of Knockout for Wiring

 

Model

Hood Width

(A)

 

 

 

PWC362418(R)

36" (914)

2" (51)

 

 

 

PWC422418(R)

42" (1067)

3" (76)

 

 

 

PWC482418(R)

48" (1219)

4" (102)

 

 

 

PWC542418(R)

54" (1372)

4" (102)

 

 

 

Letter (A) corresponds to the illustration.

Location of wiring

12

Image 12
Contents Installation Instructions N TA C T F O R M AT I O N Installation R E Q U I R E M E N T S L F PRO Wall Chimney V E N T I L AT I O N H O O D SAT I N G P L AT E I N F O R M AT I O N Wall Chimney Hood Rail Option Installation S P E C I F I C AT I O N S Overall D I M E N S I O N SRO WA L L C H I M N E Y H O O D S Letters correspond to those in the illustrations Installation I N S T R U C T I O N S S TA L L Ductwork Framing for wall chimney hoods Be careful not to remove the two other Duct cover installation Hood installation T E R N a L B L O W E R W I R I N G P O RTA N T N OT EInstallation I N S T R U C T I O N S S TA L L Wiring L I N E O R R E M OT E B L OW E R W I R I N GFilter I N S TA L L AT I O N Wolf N a M E P L AT E Installation I N S T R U C T I O N S Internal B L O W E R S B L O W E R 6 0 I N T / C T B L O W E R 9 0 I N TO W E R I N S TA L L AT I O N T E R N a L B L O W E R S M OT E B L O W E R SYO U N E E D Service Troubles H O OT I N GPage 0 4 8 0 0