Electrical Requirements
Verify that power is disconnected from the electrical box before proceeding.
The Wolf electric grill module requires a separate, grounded
MODEL IG15/S
•Power supply: 240/208 V AC, 60 Hz, 20 amp service.
•Max connected load: 2.8 kW at 240 V, 2.1 kW at 208 V.
The grill module is provided with a 4' (1.2 m) flexible
IMPORTANT NOTE: You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
For electrical installation, attach the conductors to the residence wiring in accordance with National Electrical Codes and all state, provincial, municipal and local codes.
The wiring diagram covering the control circuit is located inside the module control box.
IMPORTANT NOTE: This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appli- ance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate located on the under- side of the module. Refer to the illustration on page 3.
The complete appliance must be properly grounded at all times when electrical power is applied.
Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must be utilized.
If aluminum house supply wiring is utilized, splice the appliance copper wire to the aluminum house wiring using special connectors designed and agency certified for joining copper and aluminum. Follow the connector manufacturer’s recommended procedure carefully. Improper connection can result in a fire hazard!