Viking DGSU100, F20863 EN, DGSU1605BGG manual To Prevent Fire or Smoke Damage, Getting Started

Page 3

Getting Started

IMPORTANT– Please Read and Follow

Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution, and care must be exercised when installing, maintaining, or operating this appliance.

ALWAYS contact the manufacturer about problems or conditions you do not understand.

Recognize Safety Symbols, Words, Labels

DANGER

Hazards or unsafe practices which WILL result in

severe personal injury or death

WARNING

Hazards or unsafe practices which COULD result in

death or severe personal injury

CAUTION

Hazards or unsafe practices which COULD result in

minor personal injury or property damage. All safety messages will identify the hazard, tell you

how to reduce the chance of injury, and tell you what can happen

if the instructions are not followed.

Read and follow all instructions before using this appliance

to prevent the potential risk of fire, electric shock, personal injury or damage to the appliance as a result of improper usage of the appliance. Use appliance only for its intended purpose as described in this manual.

To ensure proper and safe operation: Appliance must be properly installed and grounded by a qualified technician. DO NOT attempt to adjust, repair, service, or replace any part of your appliance unless it is specifically recommended in this manual. All other servicing should be referred to a qualified servicer. Have the installer show you the location of the gas shutoff valve and how to shut it off in an emergency. A certified technician is required for any adjustments or conversions to Natural or LP gas.

IMPORTANT– Please Read and Follow

WARNING

If the information in this guide is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

WHAT TO DO IF YOU SMELL GAS:

DO NOT try to light any appliance.

DO NOT touch any electrical switch.

DO NOT use any phone in your building.

• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING

To avoid risk of property damage, personal injury or death; follow information in this guide exactly to prevent a fire or explosion. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any appliance.

To Prevent Fire or Smoke Damage

Be sure all packing materials are removed from the appliance before operating it.

Keep area around appliance clear and free from combustible materials, gasoline, and other flammable vapors and materials.

If appliance is installed near a window, proper precautions should be taken to prevent curtains from blowing over burners.

NEVER leave any items on the cooktop. The hot air from the vent may ignite flammable items and may increase pressure in closed containers which may cause them to burst.

Many aerosol-type spray cans are EXPLOSIVE when exposed to heat and may be highly flammable. Avoid their use or storage near an appliance.

Many plastics are vulnerable to heat. Keep plastics away from parts of the appliance that may become warm or hot. DO NOT leave plastic items on the cooktop as they may melt or soften if left too close to the vent or a lighted surface burner.

Combustible items (paper, plastic, etc.) may ignite and metallic items may become hot and cause burns. DO NOT pour spirits over hot foods.

Getting Started

4

5

Image 3
Contents Viking Use & Care Manual Congratulations Table of ContentsGetting Started To Prevent Fire or Smoke DamageCase of Fire Child SafetyCooking Safety Cookware SafetyImportant notice regarding pet birds Cleaning SafetyPower Failure Glass Ceramic Cooking SurfacesDesigner 30W. Four Burner Before Using Cooktop Cooktop FeaturesAll models include CookwareSurface Operation Cleaning and Maintenance Cooking Substitutes ChartsControl Panel Burner HeadBurner Base Cooktop SurfacesCleaning Problems on Glass Ceramic Top Problem Cause To Prevent To RemoveGlass Ceramic Top Troubleshooting Problem Cause To Prevent ToRemoveProblem Possible Cause and/or Remedy Warranty Service InformationWarranty Service

DGSU1605BSSLP, DGSU1004BSS, DGSU1605BBK, DGSU100, F20863 EN specifications

The Viking F20863 series, including models DGSU1004BSLP, DGSU1605BGG, DGSU1605BBKLP, and DGSU1605BSSLP, represents a notable advancement in industrial and commercial cooling systems. These models are engineered for various applications, ensuring a reliable solution for both high-performance needs and energy efficiency.

One of the hallmark features of the Viking F20863 series is its advanced cooling technology, which incorporates a highly efficient compressor. This component not only reduces power consumption but also enhances the overall cooling performance, making these units ideal for environments requiring consistent temperature control. With energy efficiency ratings that often exceed industry standards, users can expect to see reduced operational costs over time.

The DGSU1004BSLP model stands out for its compact design, allowing it to seamlessly fit into limited space areas while still delivering robust cooling performance. This makes it a versatile choice for smaller commercial settings where space is a premium. In contrast, the DGSU1605BGG and DGSU1605BBKLP models offer larger capacities, catering to bigger operations and ensuring that even in high-demand scenarios, performance does not falter. The stainless steel finish of the DGSU1605BSSLP variant not only provides aesthetic appeal but also contributes to durability and ease of cleaning.

In terms of technology, these models are equipped with smart control systems that allow for precise temperature regulation. This feature is particularly beneficial in settings where temperature consistency is paramount, such as food storage or medical applications. Additionally, the units are designed with noise-reduction technologies, ensuring that they operate quietly, which is crucial in work environments.

Another significant characteristic of the Viking F20863 series is its user-friendly interface, allowing for straightforward operation and programming. With features such as programmable timers and multiple cooling settings, users have complete control over their cooling systems to suit their specific needs.

Overall, the Viking F20863 series, with models like DGSU1004BSLP, DGSU1605BGG, DGSU1605BBKLP, and DGSU1605BSSLP, exemplifies the convergence of efficiency, technology, and design. These cooling solutions are engineered to meet the demands of modern industrial and commercial applications, providing reliability and quality that users can depend on. This series not only addresses performance needs but also emphasizes sustainability, making it a smart choice in today’s environmentally-conscious market.