Electrical Requirements

General Information

Electrical Requirements

Check your local codes regarding this unit. This cooktop is supplied with a 3-wire, A.C. 208Y/120 volt or 120/240 volt, 60 HZ electrical system. A white (neutral) is not needed for this unit. See next section for grounding instructions. It should be fused separately.

Refer to the specifications chart and the identification label on the bottom of the burner box for kilowatt rating and recommended amperage. House wiring and fusing must comply with local codes. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA-70 – latest edition.

Electrical Connection

WARNING

The electrical power to the unit must be shut off while line

connections are being made. Failure to do so could result

in serious injury or death.

When making the wire connections, use the entire length of the conduit provided (3 feet). The conduit must not be cut.

Connect the red and black leads from the unit conduit to the corresponding leads in the junction box. The bare ground wire in the conduit is connected to the unit frame. When connecting to a 3-conductor branch circuit, if local codes permit, connect the bare ground connector lead of the unit to the branch circuit neutral (gray or white in color).

READ AND FOLLOW ALL WARNING AND CAUTION INFORMATION WHEN INSTALLING THIS APPLIANCE.

All openings in the wall behind the appliance in the floor under the appliance shall be sealed

Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors.

Disconnect the electrical supply prior to servicing or cleaning.

When removing the cooktop for service and/or cleaning, disconnect AC power supply.

Electrical requirements are listed in the product specifications under the “Electrical Requirements” section.

WARNING

ELECTRICAL

GROUNDING

INSTRUCTIONS

This cooktop must be electrically grounded in accordance with local codes or, in the absence of codes, with the National Electrical Code, ANSI/NFPA-70

latest edition. FOR PERSONAL

SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

WARNING

This appliance shall not be used for space heating. This information is based on safety considerations.

WARNING

FIRE AND ELECTRICAL SHOCK HAZARD

DO NOT use an extension cord with this appliance. Such use may result in fire, electrical shock, or other personal injury.

CAUTION

Be sure the electric power is off from the breaker box to the

junction box until the cooktop is installed and ready to

operate. The junction box should be connected to a suitable ground. DO NOT use aGFI circuit.

10

11

Image 6
Contents Installation Table of Contents Electric Cooktop DimensionsSAFETY, this Appliance Must be Properly Grounded Side viewSpecifications Cutout DimensionsProximity to Side Cabinet Installation Wall InstallationIsland Installation Minimum Clearances from Adjacent Combustible ConstructionElectrical Requirements General Information Electrical RequirementsElectrical Connection Performance Checklist Final PreparationService & Registration Viking RANGE, LLC Preferred ServiceFront Street Greenwood, Mississippi 38930 USA