Viking F21213 Wall Installation, Island Installation, Proximity to Side Cabinet Installation

Page 5

Clearance Dimensions (Proximity to Cabinets)

Clearance Dimensions (Wood/Composite Overlay)

Proximity to Side Cabinet Installation

The cooktop may be installed directly to

 

existing base cabinets.

The cooktop CANNOT be installed

 

directly adjacent to sidewalls, tall cabinets,

 

tall appliances, or other side vertical

 

surfaces above 36” (91.4 cm) high. There

 

must be a minimum of 6” (15.2 cm) side

 

clearance from the cooktop to such

 

combustible surfaces above the

 

36” (91.4 cm) counter height.

Within the 6” (15.2 cm) side clearance to

 

combustible vertical surfaces above

 

36” (91.4 cm), the maximum wall cabinet

 

depth must be 13” (33.0 cm) and wall

 

cabinets within this 6” (15.2 cm) side

 

clearance must be 18” (45.7 cm) above

 

the 36” (91.4 cm) high countertop.

Minimum Clearances from Adjacent Combustible Construction

Above countertop 36” (91.4 cm) minimum

Side 6” (15.2 cm)

Rear 0” (0.0 cm)

Within 6” side clearance. Wall cabinets no deeper than 13” (33.0 cm)

Must be minimum 18” (45.7 cm) above countertop

Wall cabinets directly above the product must be minimum 36” (91.4 cm) above the countertop

The bottom of a standard hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the rangehood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood.

Wood/CompositeOverlay

(167.66”min.

6

cm)

to

(182.72”max.

9

cm)

 

24”

.0

cm)

(61

 

30”min.(76.

2

cm)

 

 

to

36”max.

(91.

 

 

4

cm)

 

 

 

 

 

• Wall cabinet above the cooktop

must be a minimum of 36”

(91.4 cm) above the countertop

for a full width of the cooktop.

The minimum height requirement

does NOT apply if a rangehood is

installed over the cooking surface.

 

 

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

max

 

 

 

 

 

 

 

13”

0

cm)

 

 

 

 

 

 

 

(33

.

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

min

 

 

 

 

 

 

 

 

 

36”

cm)*

 

min

 

 

 

 

 

 

.4

 

 

 

 

 

 

 

 

(91

 

18”

 

cm

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.7

 

 

 

 

 

 

 

 

 

 

(45

 

 

 

6”

 

 

 

 

 

 

 

 

 

 

(15.

 

min

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

cm)**

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood/CompositeOverlay

 

 

(167.66”min.

6

cm)

to

(182.72”max.

9

cm)

 

 

30”

.2

cm)

(76

 

 

6”

 

.2

cm)

(15

 

 

Wall Installation

30”min(76. .

2

cm)

 

to

36”max.

(91.

 

4

cm)

 

 

 

 

.

 

 

min

36”

4

cm)

(91

.

 

 

 

 

 

Dimensions shown are for use with combustible surfaces unless otherwise stated.

*Note: 36” minimum unless using a hood.

**Note: Only applies to combustible surfaces.

***Note: Refer to installation of holddown brackets on page 13 for minimum clearances under counter

 

3

 

 

-

(7

.

1/8”

 

 

9

cm)

 

 

(0

0”

min

 

.

 

 

 

0

cm)

.

 

 

 

 

 

 

Island Installation

8

9

Image 5
Contents Installation Table of Contents SAFETY, this Appliance Must be Properly Grounded DimensionsElectric Cooktop Side viewCutout Dimensions SpecificationsIsland Installation Wall InstallationProximity to Side Cabinet Installation Minimum Clearances from Adjacent Combustible ConstructionElectrical Connection Electrical Requirements General InformationElectrical Requirements Final Preparation Performance ChecklistFront Street Greenwood, Mississippi 38930 USA Service & RegistrationViking RANGE, LLC Preferred Service