Dukane CAE-20W instruction manual Precautions for Installation

Page 49

Precautions for Installation

More

Than

10 cm

Front

side

More

Than

10 cmMore Than 10

cm

Precautions for Installing the Infrared Receiver and Infrared Receiver/Amplifier

Infrared Receiver and Infrared Receiver / Amplifier will produce small amounts of heat. Provide a minimum of 10 cm when installing the amplifier close to the ceiling or wall.

￿Infrared Receiver and Infrared Receiver / Amplifier are for indoor use only. They cannot be installed and used in any of the situations below:

In a place where they can get wet.

Where chemicals are used including under the eaves (ex. pool)

Places that contain high amounts of steam, oil, or a flammable atmosphere.

Places where radiation, such as X-ray or high radio waves magnetism are present. On the ocean, beach or place where corrosive gas, such as hot spring is present.

In a place where high levels of vibration are present such as on a vehicle, or marine ves sel.

When using the provided bracket, note the following points. Select a sturdy wall to install.

Insure that the appropriate fasteners or screws are used, and that they are rated appro priately for the load they will be required to carry.

Insure that all the all directions from the manufacturer of the anchor, fastener or screw are followed.

Do a visual check and make sure that nothing is unsteady and the screws are tight. Note the following points when tightening bolts and screws.

Proper torque must be applied to all bolts and screws.

A torque wrench or a torque driver are required to set the proper torque.

It is difficult to get the proper torque with an impact driver or electric driver even if it has a clutch; therefore, they should not be used as they may damage the parts for the installa tion.

Note the following points when installing the Innovator or Ultimate II Infrared Receiver/ Amplifier into a rack.

When mounting to a rack, remove the rubber feet from the base of the unit.

When installing near other heat-sensitive equipment, install the other equipment lower than the receiver/amplifier system.

Install rack in a such a manner as to provide for sufficient airflow to maintain a tempera ture of no more than 40￿ in the rack.

49

Image 49
Contents Product Instruction Manual Table of Contents Table of Contents Introduction Introduction English CE DeclarationSwedish Safety Instructions Safety Instructions Explanation of Symbols Operating Controls Identification AchieverUltimate Ultimate Operating ControlsUltimate Iise Rear Panel Connections FunctionULTIMATE Iise Setting the Function Channel on the Teacher microphoneAmplifier Function Output Connections Function Action DescriptionInnovator Operating Controls RC-07 Infrared Receiver RC-07 Infrared Receiver Student Microphone Teacher Microphone Charging the Microphone Battery SoloSolution EDS-07 IR Sensor AE-DCF Coupler Example Student Microphone Example Teacher Microphone Operating ProcedureUsing the Remote Volume Control 【Note】 Using the Microphone as a TransmitterMute functions work as depicted below Setting the Aux MuteAE-DCF InstallationBasic Connections for the Ultimate ConnectionsBasic Connections for the Achiever AchieverEDS-07 Basic Connections for the RC-07For Reception in Large Areas Fix coaxial cable Ceiling Sensor Floor Precautions for Installing the SensorsInstallation Install the sensor Installing the Sensors PartAfter installation, make sure nothing is loose Cut a hole in the ceiling panelInstallation Bracket Diagram for bending Receiving from1ch/2ch3ch/4ch When using the AE-DCF sensor coupler Installation Coaxial Cables【Caution】 Part 2 Good example Part 1 Good examplePart 3 Bad example Mute function works as shown below Setting the PA Aux MutePA hot signal PA cold signal Jumper Setting the EMG Aux MuteTorque for the screws is 0.98 N・m±0.1 N・m 10 kgf・cm±1 kgf・cm Information about Connectors Serial transmission connection RS232C specificationsAbout External Control About connectionsPrecautions for Installation Installing the Bracket Wire lope Maximum weight allowed on the mount is 55 lbs MTBR-07S BT77 Bracket Innovator Ultimate Achiever RC-07 Fuse Part NumbersTeacher’s Check List Troubleshooting Transmitter is not working Troubleshooting No Audio Repair Form Audio EnhancementPower Cords for EU For Your Safety Please Read the Following Text Carefully Safety Instructions for EUHow to replace the fuse For business users in the European Union Weee FittingStandard 5-year Warranty

CAE-20W specifications

The Dukane CAE-20W is an advanced ultrasonic welding machine renowned for its precision and efficiency in various industrial applications. Designed for high-performance, this model combines cutting-edge technologies with user-friendly features, making it a preferred choice in sectors like automotive, medical device manufacturing, and consumer goods.

One of the standout features of the CAE-20W is its state-of-the-art ultrasonic technology. This machine utilizes high-frequency sound waves to create a strong bond between materials, typically thermoplastics. The ultrasonic vibrations generate localized heat at the weld area, enabling seamless and robust joints without the need for adhesives or additional fasteners. This method not only enhances the strength of the weld but also reduces cycle times, boosting overall productivity.

The CAE-20W boasts a user-friendly interface that allows operators to easily set and adjust parameters, including amplitude, time, and pressure. This level of control ensures consistent quality in welding processes, which is crucial for industries where precision is paramount. The machine also incorporates advanced diagnostic tools that provide real-time feedback, helping to troubleshoot issues quickly and maintain operational efficiency.

Another notable characteristic of the CAE-20W is its versatility. The machine supports various material types, from standard plastics to engineered thermoplastics, making it a flexible solution for manufacturers with diverse product lines. It can accommodate different welding tools and fixtures, enabling quick changes for various applications, thus supporting multiple production runs without significant downtime.

In terms of safety, the CAE-20W is equipped with several safety features, including emergency stop buttons and protective covers. These mechanisms ensure that operators can work in a secure environment, minimizing the risk of accidents during operation.

Furthermore, the Dukane CAE-20W is designed with a compact footprint, making it suitable for small to medium-sized manufacturing spaces. Its robust construction ensures durability and longevity, even in demanding production environments. Overall, the CAE-20W stands out as a reliable and efficient ultrasonic welding solution, integrating advanced technology and practical features to meet the needs of modern manufacturing.