-Manual calibration: (or upon request) is set in the configuration menu. This procedure is advised, and may be started, in case of malfunctioning of the sensor (which, for example, may occur in case of blackout while cooking or after a long time since the use).
For the manual calibration, proceed with the steps below:
•with the hood OFF or in standby, the menu is accessed by pressing the T6 and T7 buttons for a prolonged time; this is signalled by a sound emitted by the hood and by the I4 icon lighting up and the writing
•use the buttons T6 and T7 to go through the menu. Use T6 to go through the various menu items (C1, C2, C3, C4, etc) and T7 to select them (0, 1 or 0, 1, 2);
•for the manual calibration, access the menu, select item C4 with T6 and set value 1 with T7. Then press T1 and wait for the time suggested for the calibration.
Selecting the hob type: the type of hob (electric, induction, gas) present under the hood is select upon installation. A complete automatic calibration procedure is carried out immediately after selecting the hob.
Important: do not force the calibration “upon request” after selecting the hob as this activates automatically.
To select the hob, proceed as follows:
•with the hood OFF or in standby, the menu is accessed by pressing the T6 and T7 buttons for a prolonged time; this is signalled by a sound emitted by the hood and by the I4 icon lighting up and the writing
•use the buttons T6 and T7 to go through the menu. Use
T6 to go through the various menu items (C1, C2, C3, C4, etc) and T7 to select them (0, 1 or 0, 1, 2);
•to select the hob, access the menu, select item C3 with T6 and set the value with T7 to 0 if you have a gas hob, 1 if you have a radiant hob and 2 if you have an induction hob. Press T1 to leave the menu mode and wait the time needed for the sensor calibration.
Hood type setting
The hood can be set in the ventilation (default) and filtering operating mode. To change the type proceed as follows:
•with the hood OFF or in standby, the menu is accessed by pressing the T4 and T5 buttons for a prolonged time; this is signalled by a sound emitted by the hood and by the I4 icon lighting up and the writing
•use the buttons T4 and T5 to go through the menu. Use
T4 to go through the various menu items (C1, C2, C3, C4, etc) and T5 to select them (0, 1 or 0, 1, 2);
•to set the hood type, access the menu, select the item
C6 with T4 and set the value 0 with T5 to set the hood on ventilation mode or 1 for the filtering mode. Then press T1.
Hood off
The hood can be turned off manually by pressing the T1 button (ON/OFF). If the hood stays on in manual mode, it turns off automatically after a certain “safety” time. If the timer is set, the hood turns off automatically when the set time runs out. The Automatic mode activates after 10 minutes from the sensor turning off the hood motor.
Configuration table |
|
|
| |
|
| GB | ||
|
|
|
| |
|
|
|
|
|
Regulation | Meaning | Explanation |
| |
code |
|
|
|
|
C1 | Grease filter timer | It resets the grease |
| |
filter timer |
|
| ||
|
|
| ||
C2 | Odour filter timer | It resets the odour filter |
| |
timer |
|
| ||
|
|
| ||
|
| It changes the hob type |
| |
C3 | Hob type | for the AUTO sensor. It |
| |
may be gas, electric or |
|
| ||
|
|
| ||
|
| induction |
| |
|
| It calibrates the sensor. |
| |
|
| If item 1 is select, the |
| |
C4 | Sensor calibration | sensor carried out the |
| |
calibration the next |
|
| ||
|
|
| ||
|
| time the hood is turned |
| |
|
| on |
| |
|
| If mute, no FB audio is |
| |
C5 | Audio levels | emitted (not even when |
| |
|
| turning ON) |
| |
C5 | Hood type | Ventilation/Filtering |
| |
(Ventilation by default) |
|
| ||
|
|
| ||
| Reset to Factory | It resets the DGT menu |
| |
C6 | values to default values |
| ||
| default | (including installation) |
|
|
|
|
|
General notes
If the display buttons become locked, unplug and plug in again the hood from the mains before contacting the Assistance Service.
Maintenance and care
Caution! Before cleaning or servicing the unit, disconnect it from the mains by pulling the power plug or disconnecting the main circuit breaker.
First cleaning
•Remove the protective film
•Clean with a damp sponge and a little neutral soap
•Rinse off with a damp cloth
•Dry with a soft cloth; if the hood is stainless steel, dry along the metal's grain
Periodic cleaning
The hood must be cleaned frequently (at least as often as you service the grease filter), inside and out. Use a damp cloth and a neutral liquid detergent with lukewarm water.
Do not use abrasive or corrosive products.
Warning: Failure to observe the hood cleaning and filter cleaning/replacement instructions can result in fires. Follow the instructions carefully. The manufacturer is not liable for any damage to the motor or fires caused by incorrect care or failure to follow the above instructions.
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
13