Whirlpool IH7302RS0 Installation Requirements, Tools and Parts, Location Requirements

Page 4

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the safety instructions provided with any tools listed here.

Tools needed:

level

drill with 1¹⁄₄" (3.2 cm), ³⁄₈" (9.5 mm), ⁷⁄₆₄" (2.75 mm) and ¹⁄₈" (3 mm) drill bits

pencil

wire stripper or utility knife

measuring tape or ruler

pliers

caulking gun and weatherproof caulking compound

duct tape

jig saw or keyhole saw

flat blade screwdriver

metal snips

metric Allen wrench set

Parts needed:

1 x ¹⁄₂" conduit

1 wall or roof cap

metal vent system

2 charcoal filters – for non-vented (recirculating) installations only

Parts supplied:

Remove parts from packages. Check that all parts were included.

hood canopy assembly with ventilator, light bulbs and transition with back draft dampers installed

deflector for non-vented (recirculating) installations

Installation Instructions and Use & Care Guide

filter(s) – depending on model and size

screws and drywall anchors

2 mounting hooks

mounting template

2 piece vent cover

rubber tape

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical Requirements” section.

The canopy hood is factory set for venting through the roof or wall. For non-vented (recirculating) installations see “Non-Vented (Recirculating) Installations” in “Install Vent” section.

All openings in ceiling and wall where canopy hood will be installed must be sealed.

Product Dimensions

 

8"

 

(20.3 cm)

4¹¹⁄₁₆"

8"

(20.3 cm)

(11.9 cm) min.

13¹³⁄₁₆"

(35.1 cm) max.

20⁷⁄₈"

(53.0 cm) min.

30"

(76.2 cm) max.16 ³⁄₈"

(41.6 cm)

14 ⁵⁄₈"

(37.1 cm)

30"

19"(76.2 cm) (48.3 cm)

4

Image 4
Contents 30 76,2 cm 9760267A1Range Hood Safety Table of ContentsTable DES Matières Important Safety Instructions Installation Requirements Product DimensionsTools and Parts Location RequirementsInstallation Clearances Venting RequirementsVenting methods Calculating Vent System LengthElectrical Requirements Installation InstructionsPrepare Location Vent Cover Bracket Installation Install Range HoodInstallation locations with reduced ceiling heights Install Vent Vented InstallationsNon-Vented Recirculating Installations Make Electrical ConnectionInstall Filters Complete InstallationCheck Operation Cleaning Range Hood USERange Hood Care OperationAssistance or Service AccessoriesRange Hood Warranty Whirlpool Corporation will not pay forWiring Diagram Sécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteConservez CES Instructions Exigences Dinstallation Exigences demplacementDimensions du produit Outillage et piècesExigences concernant lévacuation Espacements dinstallationMéthodes dévacuation Spécifications électriques Calcul de la longueur effective du circuit dévacuationInstructions Dinstallation Préparation de lemplacementInstallation de la hotte de cuisinière Installation du circuit dévacuationInstallation de la bride du cache-conduit Installation avec décharge à lextérieurInstallation sans décharge à lextérieur recyclage Achever linstallationRaccordement électrique Installation des filtres Contrôle du fonctionnementFonctionnement CuisinièreNettoyage Accessoires Installation des filtres à charbonRemplacement des filtres à charbon Remplacement dune lampeAssistance OU Service Pour pièces, accessoires et service au CanadaSi vous avez besoin de pièces de rechange Pour plus dassistanceGarantie DE LA Hotte DE Cuisinière Whirlpool Corporation ne paiera pas pourSchéma DE Câblage NEU L9760267A