Whirlpool IH7302RS0 Complete Installation, Install Filters, Check Operation

Page 9

Complete Installation

1.Install vent cover.

When using both upper and lower vent cover, push lower cover down onto hood and lift upper cover to ceiling and install screws.

A

B

A. Upper vent cover

B. Lower vent cover

For reduced ceiling height installations, when using only the lower cover, push lower cover down onto hood and snap vent into place around vent cover bracket.

Install Filters

1.For non-vented (recirculating) installations, install charcoal filter over grill on blower housing and turn filter handle clockwise. Repeat with other charcoal filter.

A

B

C C

A. Blower housing

B.Handle

C.Charcoal filters

2.For all installations, insert back edge of metal filter into rear channel of the filter opening.

3.Push handle toward the rear and push filter up.

4.Pull filter toward the front and insert into front channel.

Check Operation

1.Check operation of the range hood by turning the power on.

A

B

O I

O 1 2 3

A. Light switch

B. Blower switch

2.Move the light switch to the “1” position. The light should turn on.

3.Move the light switch to the “0” position. The light should turn off.

4.Move the blower switch to the “1” position for low speed. “2” position for medium speed. “3” position for high speed.

5.Move the blower switch to the “0” position. The blower should turn off.

6.If range hood does not operate, check that the circuit breaker has not been tripped or the house fuse blown. Disconnect power supply and check that the wiring is correct.

9

Image 9
Contents 9760267A1 30 76,2 cmTable of Contents Range Hood SafetyTable DES Matières Important Safety Instructions Product Dimensions Installation RequirementsTools and Parts Location RequirementsVenting Requirements Installation ClearancesVenting methods Calculating Vent System Length Installation Instructions Electrical Requirements Prepare Location Install Range Hood Vent Cover Bracket InstallationInstallation locations with reduced ceiling heights Vented Installations Install VentNon-Vented Recirculating Installations Make Electrical ConnectionComplete Installation Install FiltersCheck Operation Range Hood USE CleaningRange Hood Care OperationAccessories Assistance or ServiceWhirlpool Corporation will not pay for Range Hood WarrantyWiring Diagram Votre sécurité et celle des autres est très importante Sécurité DE LA Hotte DE CuisinièreConservez CES Instructions Exigences demplacement Exigences DinstallationDimensions du produit Outillage et piècesEspacements dinstallation Exigences concernant lévacuationMéthodes dévacuation Calcul de la longueur effective du circuit dévacuation Spécifications électriquesPréparation de lemplacement Instructions DinstallationInstallation du circuit dévacuation Installation de la hotte de cuisinièreInstallation de la bride du cache-conduit Installation avec décharge à lextérieurAchever linstallation Installation sans décharge à lextérieur recyclageRaccordement électrique Contrôle du fonctionnement Installation des filtresCuisinière FonctionnementNettoyage Installation des filtres à charbon AccessoiresRemplacement des filtres à charbon Remplacement dune lampePour pièces, accessoires et service au Canada Assistance OU ServiceSi vous avez besoin de pièces de rechange Pour plus dassistanceWhirlpool Corporation ne paiera pas pour Garantie DE LA Hotte DE CuisinièreNEU L Schéma DE Câblage9760267A