Hotpoint SD33X, SHS33XK S, SH33K S, SH33W S, SHS33X S, SH33X S, KSO33CX S manual Electrical Connection

Page 5
Electrical Connection

Electrical Connection

The electrical connection to the mains must be made on the appliance. The power voltage and frequency are as indicated on the rating plate.

!THIS APPLIANCE MUST BE EARTHED. Fitting the power supply cable

Unplug the appliance before all operations, even

when replacing the oven lamp.GB Using the appliance without correct earthing is highly dangerous.

!After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.

APPLIANCE SPECIFICATIONS

Dimensions*

width 43.5 cm

height 32,4 cm

L

N

1.Open the terminal board by inserting a screwdriver into the side tabs of the cover. Use the screwdriver as a lever by pushing it down to open the cover (see diagram)

.

2.Install the power supply cable by loosening the cable clamp screw and the three wire contact screws

L-N-Manual background.

Connect the wires to the corresponding terminals: the Blue wire to the terminal marked (N), the Brown wire to the terminal marked (L) and the Yellow/Green wire

to the terminal marked Manual background (see diagram).

 

depth 41.5 cm

 

 

Volume*

59 l

 

 

Dimensions**

width 45.5 cm

height 32,4 cm

 

depth 41.5 cm

 

 

Volume**

62 l

 

 

Electrical

voltage: 230 - 240 V~ 50/60 Hz

or 50 Hz(see data plate)

connections

maximum power absorbed

 

2250-2400 W

 

 

 

Directive 2002/40/EC on the label

ENERGY

of electric ovens. Standard EN 50304

 

LABEL

Declared energy consumption for

 

 

Forced convection Class - heating

 

mode: Fan assisted

This appliance conforms to the following European Economic Community directives:

- 2006/95/EEC of 12/12/06 (Low

Voltage) and subsequent

3.Secure the cable by fastening the clamp screw.

4.Close the cover of the terminal board.

Electrical Connection:

Voltage Frequency: see data plate

Fuse Section: 16A

Supply cable: 3x1.5mm2

You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.

If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3mm - should be installed between the appliance and the mains.

Power cable supply connection to the electrical mains:

We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.

The plug must be accessible at all times.

amendments;

- 2004/108/EEC of 15/12/04 (Electromagnetic Compatibility) and subsequent amendments;

- 93/68/EEC of 22/07/93 and subsequent amendments.

-2002/96/EC and subsequent amendments.

*Only for models with drawn rails.

**Only for models with wire rails.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

5

Image 5
Contents OVENContents Operating Instructionsguarantee SH33K S SH33W S SH33X S SHS33X S SHS33XK SGB Warnings Control panel Description of the applianceOverall view Positioning GB InstallationElectrical Connection Modes GB Start-upand usePractical cooking advice Starting the ovenPIZZA Cooking advice tableSetting the clock GB The electronic programmerSetting the timer Programming cookingMaintenance and care Precautions and tipsGeneral safety Switching the appliance offReplacing the light bulb Cleaning the oven doorSide and rear catalytic liners Inspecting the sealsEssential Contact Information Afetr Sales ServiceHotpoint Service Parts and Accessories12 months Parts and Labour Guarantee GB Guarantee5 Year Parts Guarantee Extended Guarantees