Wells BT-4C, T-4C, T-4C 15A Installation, Unpacking & Inspection, Setup, Electrical

Page 6

INSTALLATION

NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation.

Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual.

DO NOT lift or carry the toaster by the bread slots. This will damage the heating elements Lift and carry by the carrying handles only.

CAUTION:

Electric Shock

Hazard

The ground prong of the power cord is part of a system designed to protect you from electric shock in the event of internal damage to the appliance.

NEVER CUT OFF THE GROUND PRONG (large round prong).

NEVER TWIST A PRONG TO FIT AN EXISTING RECEPTACLE.

If circuit or receptacle does not match the toaster plug, contact a licensed electrician to install an electrical receptacle appropriate to the voltage and amperage requirements of the toaster.

IMPORTANT:

Damage due to being plugged into the wrong voltage or phase is NOT covered by warranty

UNPACKING & INSPECTION

Carefully remove the toaster from the carton. Remove all protective plastic film, packing materials and accessories from the toaster before plugging the toaster into electrical power or otherwise performing any installation procedure.

Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the toaster before starting any installation.

Read and understand all labels and diagrams attached to the toaster.

Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use.

SETUP

Setup the toaster only on a firm level surface. Non-combustible material (e.g. metal, terrazzo) is recommended.

ELECTRICAL

Refer to the nameplate. Verify the electrical service power. Voltage and phase must match the nameplate specifications. Plugging the toaster into the wrong voltage can severely damage the equipment or cause noticeably decreased performance.

Your appliance is equipped with a grounded electric power cord. This cord must be plugged into a properly grounded electrical receptacle.

T-4C Toasters are equipped with a 4 foot cord with grounded NEMA

6-15P plug. This cord must be plugged into a 208 or 240 volt, 15 amp circuit with a properly installed and grounded NEMA 6-15R receptacle. Refer to toaster nameplate for proper voltage.

T-4C 15A Toasters and BT-4C Bagel Toasters are equipped with a 4 foot cord with grounded NEMA 5-15P plug. This cord must be plugged into a 120 volt, 15 amp circuit with a properly installed and grounded NEMA 5-15R receptacle.

4

Image 6
Contents For Important do not Discard this ManualLimited Warranty Statement Table of Contents SpecificationsFeatures & Operating Controls Bread SlotsElectric Shock hazard Precautions and General InformationAgency Approval Information Risk DamageUnpacking & Inspection InstallationSetup ElectricalOperation General Operational NotesOperation Preparation Cleaning InstructionsCleaning FrequencyTroubleshooting This page Blank Parts & Service Description ServiceWells Manufacturing Co