MAINTENANCE PROCEDURES (continued)
During
A MENU cycle cannot be started while in
Program mode is disabled when either timer is counting down.
A programmed cycle cannot be started when display is flashing
Any changes to the left preset timer programs are copied right section. The right program settings can then be changed and stored. Right program settings are retained until the left section is reporgrammed, at which time left program information is again copied to the right section.
When setpoint temperature is reached, the display stops flashing and the audible alert beeps 3 times.
STANDARD OPERATION NOTES:
Standard
PROGRAM | TEMP | TIME | FUNCTION |
1 | 450º | 00:14 |
|
2 | 450º | 00:27 |
|
3 | 450º | 00:35 |
|
4 | 275º | 00:00 | CLEANING |
On
Both lower platen zones and both upper platens are controlled by the individual setpoints. Deadband is ±2º.
Press TEMP to display actual temperature of the lower platen.
PROGRAMMING TIME AND TEMPERATURE (LEFT SECTION) NOTE:
•You may program MENU keys during
•Temperature settings are done with the left MENU only.
•Time settings are automatically copied from the LEFTMENU to the corresponding RIGHTMENU.
•Time settings on the RIGHTMENU may be programmed only after the LEFTMENU.
Example: Program time and temperature for LEFT MENU 1 Press and hold TEMP. While holding TEMP, press and hold LEFT MENU 1 key for 3 seconds. The LED above the MENU 1 key will glow, and the display will read “_ _ : _ _”, prompting you to enter the
Enter the
8