Omega Engineering TX801M manual Omega.comTM, Usa

Page 2

omega.comTM

 

 

 

OMEGA

 

 

 

 

 

OMEGAnetSM On-Line Service

 

Internet e-mail

 

http://www.omega.com

 

info@omega.com

 

 

 

 

 

 

Servicing North America:

USA:

One Omega Drive, Box 4047

 

ISO 9001 Certified

Stamford, CT 06907-0047

 

 

 

Tel: (203) 359-1660

FAX: (203) 359-7700

 

 

e-mail: info@omega.com

 

Canada:

976 Bergar

 

 

 

Laval (Quebec) H7L 5A1

 

 

 

Tel: (514) 856-6928

FAX: (514) 856-6886

 

 

e-mail: canada@omega.com

 

For immediate technical or application assistance:

USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASMCustomer Service: 1-800-622-2378 / 1-800-622-BESTSMEngineering Service: 1-800-872-9436 / 1-800-USA-WHENSMTELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA

Mexico and

 

 

Latin America:

Tel: (95) 800-TC-OMEGASM

FAX: (95) 203-359-7807

 

En Espanol: (203) 359-7803

e-mail: espanol@omega.com

 

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands

 

Tel: (31) 20 6418405

FAX: (31) 20 6434643

 

Toll Free in Benelux: 06 0993344

 

 

e-mail: nl@omega.com

 

Czech Republic:

ul. Rude armady 1868, 733 01 Karvina-Hranice, Czech Republic

 

Tel: 420 (69) 6311627

FAX: 420 (69) 6311114

 

e-mail: czech@omega.com

 

France:

9, rue Denis Papin, 78190 Trappes

 

Tel: (33) 130-621-400

FAX: (33) 130-699-120

 

Toll Free in France: 0800-4-06342

 

 

e-mail: france@omega.com

 

Germany/Austria:

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

 

Tel: 49 (07056) 3017

FAX: 49 (07056) 8540

 

Toll Free in Germany: 0130 11 21 66

 

e-mail: germany@omega.com

 

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unau- thorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibra- tion; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s con- trol. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESEN-

TATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS- CLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether

based on contract, warranty, negliegence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent break- age in transit.

United Kingdom:

25 Swannington Road,

P.O. Box 7, Omega Drive,

ISO 9001 Certified

Broughton Astley, Leicestershire, Irlam, Manchester,

 

LE9 6TU, England

M44 5EX, England

 

Tel: 44 (1455) 285520

Tel: 44 (161) 777-6611

 

FAX: 44 (1455) 283912

FAX: 44 (161) 777-6622

 

Toll Free in England: 0800-488-488

 

e-mail: uk@omega.com

FOR WARRANTY RETURNS, please have the following information available BEFORE contact- ing OMEGA:

1.P.O. number under which the product was PUR CHASED,

2.Model and serial number of the product under warranty, and

3.Repair instructions and/or specific problems relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE con tacting OMEGA:

1.P.O. number to cover the COST of the repair,

2.Model and serial number of product, and

3.Repair instructions and/or specific problems relative to the product.

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.

The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.

WARNING: These products are not designed for use in, and should not be used for, patient connected applications.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of

OMEGA ENGINEERING, INC.

Image 2
Contents Temperature PH/CONDUCTIVITYOmega.comTM USADimensions and Mounting FeaturesTX801M Specifications Proper Installation & Maintenance of TX801MTX801MInput Range Programming Table How to Use the Maths Function FormulaeExamples of Using the Maths Function Formulae Examples of Input Connection

TX801M specifications

Omega Engineering's TX801M is a highly versatile and sophisticated temperature transmitter designed for various industrial applications. Known for its robustness and reliability, the TX801M enables precise temperature measurement and monitoring, making it an essential tool for process control in different environments.

One of the main features of the TX801M is its ability to accept various input types, including thermocouples, RTDs (Resistance Temperature Detectors), and linear signals, such as 0-10V and 4-20mA. This flexibility allows the transmitter to be easily integrated into existing systems without requiring significant modifications, thus streamlining the process of upgrading monitoring and control capabilities.

The TX801M boasts advanced digital signal processing technology, which enhances its accuracy and reliability. With an impressive accuracy level of ±0.1%, users can trust that the temperature readings are precise, reducing the risk of costly errors in process management. The device also offers a wide temperature range, enabling it to operate effectively in extreme conditions, including cryogenic applications and elevated temperatures.

Another notable characteristic of the TX801M is its user-friendly design. The device features a simple configuration process that can be easily managed via its intuitive interface. A built-in LCD display provides real-time readings and diagnostics, giving users immediate access to critical information. Additionally, the unit supports various communication protocols, such as HART, Modbus, and CANopen, facilitating seamless integration into diverse industrial environments.

The rugged construction of the TX801M ensures durability and longevity, even in harsh environments. Its housing is designed to withstand mechanical stress, moisture, and exposure to aggressive chemicals. This durability makes it suitable for a wide range of applications, including petrochemical processing, food and beverage production, and pharmaceuticals.

In terms of energy efficiency, the TX801M operates with low power consumption, making it an environmentally friendly choice. Its design also includes features for enhanced electromagnetic compatibility, thus minimizing interference and ensuring reliable operation in electrically noisy environments.

Overall, Omega Engineering's TX801M temperature transmitter stands out for its combination of flexibility, accuracy, durability, and ease of use. Its advanced features make it an ideal choice for professionals seeking reliable temperature monitoring and control solutions across various industrial settings.