Frymaster 1824E Replace Heating Element under the Frypot, Replace Frypot, Cleaning a Seized Pump

Page 10

1.12Replace Heating Element under the Frypot

1.Perform Procedure 1.10, Replace Temperature Probe, Steps 1-9.

2.Remove the wires from the element by removing the nuts on each end of the element.

3.Remove the screws attaching the element bracket to the cabinet.

4.Gently slide the element out by pulling towards the front of the fryer.

5.Insert new element and reassemble in reverse order.

1.13Replace Frypot

1.Perform Procedure 1.10, Replace Temperature Probe, Steps 1-9.

2.Perform Procedure 1.3, Accessing the Control Box Electronics, Steps 1-5.

3.Perform Procedure 1.8, Replace High-Limit, Steps 1-4.

4.Disconnect the element wires.

5.Remove the screws holding the back panels to the frame.

6.Remove the screws securing the frypot to the front frame of the fryer.

7.Carefully lift the frypot from the cabinet.

8.Remove the drain valve from the old frypot and install on the new frypot.

9.Apply Loctite Sealant PST 567 to the high-limit threads. Install high-limit into the new frypot.

10.Follow the preceding steps in reverse to install the new frypot into the fryer.

11.NOTE: Apply Loctite Sealant PST 567 to all pipefittings prior to installation.

1.14Cleaning a Seized Pump

If the pump motor overloads, a circuit breaker will trip and the motor will not start until the breaker is reset. If the pump motor does not start, press the white reset button located under the component box, inside the cabinet.

If the pump starts after resetting the breaker, then something is causing the motor to overload. A major cause of overload is filtering several frypots sequentially, creating thermal overload on the motor. Allow the pump motor to cool at least 30 minutes before resuming operation, and allow time for the motor to cool between frypots.

1-7

Image 10
Contents Hour Service Hotline 8196115Page Table of Contents General Thermatron CalibrationIdentifying Parts Replace Thermatron Board Replace TransformerReplace Breakers Replace Safety Drain RelayReplace Contactor Replace Thermatron PotentiometerReplace Temperature Sensor and High-Limit Thermostat Probes Replace Heating Elements inside Frypot Replace Heating Element under the Frypot Cleaning a Seized PumpReplace Frypot Page Probe Resistance Chart Probe Resistance ChartTroubleshooting Control and Heating Problems Element Wattage/Amperage Calculation ChartsProblem Probable Causes Corrective Action Fryer repeatedly Filtration Problems Probable Causes Corrective Action Filter pump wontWiring Diagram Accessories Part Number DescriptionCabinetry Backs, Bases, Casters, Sides, Etc E, 12424E Non-FilterItem Part Number Backs, Bases, Casters, Sides, Etc. SCF 22424E and 32424E Item Part Number Door Assembly and Component Parts Part Number Description Flue Caps, Top Caps, and Related Components Item Part Number Control Panels, Wireways, and Related Components Item Part Number Electronic Components Item Part Number Filter Pan Assembly Filter ComponentsFilter Pan Caddy Assembly Item Part Number Under Fryer Filter UFF Components Component Elements and Related Components Harnesses Part Number Description Oil Discharge Assembly 106-2192Oil Return Assembly Drain Valve and Associated Parts Drain and Oil Return Components Standard 1 ½ DrainsComponent Page Wiring Connectors, Pin Terminals and Power Cords Service Hotline