To Convert Appliance For Use With Natural Gas
WARNING
Electrical power and gas must be turned off prior to conversion.
If this appliance has been converted for use with LP gas, each of the following modifications must be performed to convert the unit back to natural gas.
A. Replace all orifice spuds
Perform Steps 1 through 3 on page 6.
For Step 4: Locate the colored brass natural gas orifice spuds that were originally installed in this appliance before its conversion for use with LP gas. Observe the color of each of the spuds and note the correct burner location for each spud as shown on page 10 figures 17, 18 or 19.
Complete Steps 5, 6, and 7 on page 6 to complete the installation of natural gas main spuds in their correct locations.
Save the orifices removed from the appliance for future use. They will be needed if this appliance is again converted for use with LP gas.
B.Invert cap in appliance pressure regulator.
(See figure 13 or 14.)
With the appliance installed the appliance regulator should be located as shown in figure 8. Identify the type of appliance regulator and follow the instructions in the appropriate illustration.
C.Adjust low flame as instructed on page 8 item C.
After Steps A, B and C have been completed, check the appearance of each burner’s flame at the Hi and Lo settings against figure 16. If the flames appear too large or too small, make sure all steps were completed correctly.
9