Gas Supply Connection

A TRAINED SERVICEMAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLY CONNECTION. Leak testing of the appliance shall be conducted by the installer according to the instructions below.

Apply a non-corrosive leak detection fluid to all joints and fittings in the gas connection between the supply line shut-off valve and the range. Include gas fittings and joints in the range if connections were disturbed during installation. Check for leaks! Bubbles appearing around fittings and connections will indicate a leak. If a leak appears, turn off supply line gas shut-off valve, tighten connections, turn on the supply line gas shut-off valve, and retest for leaks.

CAUTION: NEVER CHECK FOR LEAKS WITH A FLAME.

WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.

If the alternative piping method shown in figure 8 is selected for the installation, no ground joint union is required. (The flexible appliance connector illustrated provides the union joints necessary for servicing.) When a dividing wall is present and a flexible connector is used it is recommended for convenience, in both installation and service, the flexible connector, itself, pass through the dividing wall. Any flexible connector used with this appliance must satisfy all requirements stated in the text following figure 8.

MANIFOLD PIPE

 

APPLIANCE PRESSURE

 

REGULATOR, SUPPLIED

 

(OBSERVE DIRECTION

 

OF GAS FLOW ARROW)

 

FLARE

1/2￿ NPT

UNION

ADAPTOR

PIPE

FLEXIBLE

NIPPLE

 

APPLIANCE

 

CONNECTOR

 

(5 FT. MAX)

GAS

 

FLARE

SHUT-OFF

VALVE

UNION

 

ADAPTOR

 

GAS

1/2￿ NPT

SHUT-OFF

PIPE

VALVE

 

1/2￿ NPT

 

PIPE

 

 

FIGURE 8

Unless prohibited by local codes or ordinances, a new A.G.A. - Certified, flexible metal appliance connector may be used to connect this appliance to its gas supply. The connector must have an internal diameter not less than nominal 1/2￿ NPT pipe and be no more than 5 feet in length. A 1/2￿ NPT x 1/2￿ flare union adapter is required at each end of the flexible connector. If a flexible connector is used assure that both the appliance pressure regulator and manual shut-off valve are joined solidly to other permanent hard piping (either gas supply or the appliance manifold) so as to be physically stationary.

CAUTION: Do not attempt to attach the flexible connector directly to an external pipe thread. Connection requires flare union adapters.

Pressure Testing

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa).

This appliance, as well as its individual shut-off valve, must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 PSIG (3.5 kPa).

When checking appliance regulator function, make certain pressure of natural gas supply is between 6 and 14 inches of water column or, if converted for LP gas, between 11 and 14 inches.

Electrical Wiring Information

This appliance is equipped with a grounded type power cord. A grounded outlet must be provided.

The power cord extends 45￿ outside the unit housing. The outlet should be located inside the cutout width and below the lowest most projection of the unit housing.

WARNING

ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.

WARNING

THIS APPLIANCE MUST BE DISCONNECTED FROM ITS ELECTRICAL SUPPLY AT THE WALL RECEP- TACLE BEFORE SERVICING THE APPLIANCE.

5

Image 5
Contents Installation JGCP636ADP Preparation Of Countertop Installing Cabinetry Over Your Jenn-air GrillInstallation Of Appliance Installation Of Appliance Gas Supply Connection Pressure TestingElectrical Wiring Information Replace all orifice spuds Converting Appliance For Use With LP GasInstallation Of LP Orifice Spuds Invert cap in appliance pressure regulator Low Flame AdjustmentTo Convert Appliance For Use With Natural Gas Adjust low flame as instructed on page 8 item CInstallation Of Natural Gas Orifice Spuds Burner Ignition Auto-Reignition Required Adjustments At Time Of InstallationWest Fourth STREET, North D NEWTON, IA Superficies para cocinar Prostyle Advertencia EspecialJGCP636ADP Importante Instalación del electrodoméstico Preparación para el mostradorAdvertencia Información de cableado eléctrico Conexión del suministro de gasPruebas de presión Coloque de nuevo todos los puntales del orificio Conversión del electrodoméstico para usarse con gas LPModelo DE 121.9 CM Instalación de los puntales de orificio LPModelo DE 91.44 CM Modelo DE 76.2 CMReloj para aumentarlo Ajuste de la llama bajaAdvertencia Modelo DE 121.92 CM Instalación de los puntales de orificio de gas naturalAjustes necesarios al momento de la instalación Encendido y reencendido automático del quemadorWest Fourth STREET, North D NEWTON, IA 50208 EE.UU Manuel 55,88 cm Pose de l’appareil Pose d’armoires au-dessus de votre gril Jenn-AirPréparation du comptoir Avertissement Câblage électrique Raccordement à l’alimentation en gazVérification de la pression Remplacer tous les injecteurs à orifice Conversion de l’appareil au gaz naturelModèle DE 76,2 CM 30 PO Pose des injecteurs à orifice pour gaz GPLModèle DE 121,9 CM 48 PO Modèle DE 91,4 CM 36 PO Réglage de la flamme à feu doux Inverser le capuchon dans le détendeurRégler la flamme à feu doux tel qu’indiqué page 8, point C Pour convertir l’appareil au gaz naturelModèle DE 121,2 CM 48 PO Pose des injecteurs à orifice pour gaz naturelAllumage des brûleurs et réallumage automatique Réglages requis lors de la mise en serviceWest Fourth STREET, North D NEWTON, IA 50208, ÉTATS--UNIS