6DS9 201-8FC
￿￿
6DS8 204-8
6DS9 201-8CA￿￿
Order No.
6DS8 201-8
6DS9 200-8AA￿￿
6DS8 205-8

This catalog is out of date, see note on page 1

Bus communication

Connecting cables

Connecting cables for 20-m local bus

￿To connect the interface modules for 20-m local bus to one another and to the bus converter UI. A front plug is required for the last participant on the local bus when using the cable 6DS8 201-8.. .

Ordering data

￿Connecting cable for 20-m local bus

between two interface modules for 20-m local bus, 1 plug

0.3 m MB 1.5 m EC 10 m AD

0.5 m SB 5.0 m SC 15 m ED

0.63 m UB

Front plug

Connecting cable for 20-m local bus

between two interface modules for 20-m local bus and bus con- verter UI, 2 plugs

Connecting cables for remote bus

The following two remote bus cables are recommended:

￿

Ordering data

Order No.

 

 

 

Remote bus cable

 

Standard remote bus cable

V45466-D21-B35 1)

Specify length in plain text

Length ..... m

(max. 4 km)

 

Inhouse remote bus cable

V45466-D17-B135 1)

Specify length in plain text

Length ..... m

(max. 2 km) 2)

 

 

 

 

￿

1)

Order from

 

 

ICP CC VCE

 

 

Kistlerhofstr. 170

 

 

D-81379 Munich

 

 

Tel.+49 (89) 722-22150

 

 

Fax +49 (89) 722-41032

 

 

2) When mixed with the standard remote bus cable, the total length of the

two cables must not exceed 4 km.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.3 m

MB 1.5 m EC 5 m

SC

0.5 m

SB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connecting cable for 20-m local

 

bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between interface modules for

 

20-m local bus and bus convert-

 

ers UI1 and UI2, 3 plugs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.3 m

MB 2.0 m HC 2.7 m LC

 

1.2 m

CC 2.2 m JC 5.0 m SC

 

1.5 m

EC 2.5 m KC

 

 

 

 

 

 

 

 

Connecting cable for 20-m local bus

between interface modules for

20-m local bus N-AS and bus con- verters UI1 and UI2 as well as connection distributor for 20-m local bus, 4 plugs

Connecting cable for 20-m local bus

between interface module for

20-m local bus N-AS and bus con- verters UI1 and UI2 as well as connection distributor for 20-m local bus, 5 plugs

Summary of connecting cables with description: see page 3/34.