This catalog is out of date, see note on page 1

Ordering data

Order No.

 

 

 

Options for AS 235 H basic

 

cabinet

 

 

Basic unit

 

Retrofitting of basic unit to redun-

 

dant design:

 

Central processor module

6DS1 141-8AA

EDC memory module

6DS1 844-8FA

with 4000 Kbyte user RAM

 

Backup battery for memory

W79084-U1001-B2

module

 

Interface module for I/O bus 1

6DS1 312-8BB

Synchronization module

6DS1 143-8AA

Comparator/coupler module

6DS1 142-8AA

￿Interface module for mini floppy

6DS1 326-8BB

disk unit

 

Alarm logic module

6DS1 901-8AA

Additionally required for the 4th to

 

7th extension unit:

 

With redundant design:

6DS1 312-8BB

2 interface modules for I/O bus 2

With non-redundant design:

6DS1 312-8BB

1 interface module for I/O bus 2

 

 

 

 

Retrofitting of operation

 

 

channels

 

Retrofitting to redundant operation

 

channel 1 or 2:

 

Interface module for operation

6DS1 330-8CA

channel

 

Retrofitting of operation channel 2,

 

non-redundant:

 

Interface module for operation

6DS1 330-8CA

channel

 

Automation systems

AS 235 H

 

 

 

Options for basic cabinet

 

 

 

 

 

 

 

Ordering data

 

Order No.

 

Bus connection of further

 

 

 

 

participant via 20-m local bus

 

 

 

 

Interface module for 20-m local

6DS1 202-8AB

 

 

bus N-V.24 1)

 

 

 

 

 

• Starting from standard configu-

 

 

 

 

ration 6DS2 131-...1.

 

 

 

 

 

Connecting cable for local bus

 

 

 

 

with 1 plug

0.3 m

6DS8 201-8MB

 

 

 

0.5 m

6DS8 201-8SB

 

 

 

1.5 m

6DS8 201-8EC

 

 

 

5.0 m

6DS8 201-8SC

 

 

• and with non-redundant basic

 

 

 

 

unit:

 

 

 

 

 

Front plug 2)

 

6DS9 200-8AA

 

￿Interface module for 20-m local

 

 

6DS1 223-8AA

 

 

bus N-AS

 

 

 

 

 

• and with redundant basic unit:

 

 

 

 

 

 

 

 

2 interface modules for

6DS1 223-8AA

 

 

20-m local bus N-AS

 

 

 

 

 

Connecting cable for local bus

6DS8 205-8SB

 

 

with 2 plugs, 0.5 m

 

 

 

 

 

 

 

 

 

 

Connection to single remote

 

 

 

 

bus

 

 

 

 

 

Starting from standard configura-

 

 

 

 

tion 6DS2 131-...1.

 

 

 

 

 

With non-redundant basic unit:

 

 

 

 

Interface module for 20-m local

6DS1 223-8AA

 

 

bus N-AS

 

 

 

 

 

Bus converter UI

 

6DS4 400-8AB

 

 

Connector board AF “Remote

6DS9 203-8DA

 

bus”

 

 

 

 

 

Connecting cable with 5 plugs 3)

6DS8 201-8FC

 

to connect N-AS to bus converter

 

 

 

 

1 an connection distributor for

 

 

 

Parts set for operation channel switchover

1 video relay, complete,

1 connecting cable,

1 keyboard distributor,

1 printer distributor

Retrofitting of operation channel 2, redundant:

2 interface modules for opera- tion channel

C79165-A3012-D70

6DS1 330-8CA

20-m local bus

 

With redundant basic unit:

 

as above, plus:

 

2 interface modules for

6DS1 223-8AA

20-m local bus N-AS

 

 

 

Connection to redundant

 

remote bus

 

• With standard configurations

 

6DS2 131-...2. or -...4.

 

Parts set for operation channel

C79165-A3012-D70

switchover Extension units

Bus converter UI

6DS4 400-8AB

Connector board AF “Remote

6DS9 203-8DA

bus”

 

For retrofitting of extension units EE2 and EE3:

Subrack for extension unit With mounting parts and slots for 13 I/O modules

Wire-wrap system

Maxi-Termi-Point system

Accessories for EE2 and EE3:

Cable set for power supply

For extension unit EE2

For extension unit EE3

Cable set for I/O bus

For extension unit EE2

For extension unit EE3

Cable duct Cover

I/O bus comparator and switchover module

Upgrading set with switched- mode regulator DC 5 V (6DS1 006-8AA)

6DS9 002-8BB 6DS9 002-8BA

6DS9 908-8GC 6DS9 908-8GD

6DS9 911-8GB 6DS9 911-8GC

6DS9 906-8AB 6DS9 906-8BB

6DS1 144-8AA

C79451-A3117-D29

• With standard configurations

 

6DS2 131-...1.

 

With non-redundant basic unit:

 

Interface module for 20-m local

6DS1 223-8AA

bus N-AS

 

2 bus converters UI

6DS4 400-8AB

2 connector boards AF “Remote

6DS9 203-8DA

bus”

 

Connecting cable with 5 plugs

6DS8 201-8FC

to connect N-AS to bus converters

 

1 and 2 and the connection dis-

 

tributor for 20-m local bus

 

With redundant basic unit:

 

as above, plus:

 

2 interface modules N-AS

6DS1 223-8AA

 

 

1)Max. 2 within an AS 235 consisting of basic and extension cabinets; cannot be used in ES 100 K.

2)The cable connector 6DS8 205-8.. with 2 plugs can be used as an alternative for the combination between connecting cable and front plug

3)2 plugs not used.

Siemens PLT 111 · 1999

3/15

Page 39
Image 39
Siemens appendix Options for AS 235 H basic Cabinet