This catalog is out of date, see note on page 1
| 
 | 
 | 
 | 
 | 
 | System architecture | ||
| 
 | 
 | 
 | 
 | 
 | 
 | Configuring | |
| 
 | 
 | 
 | 
 | 
 | Standard function blocks | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| Driver blocks for I/O modules | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |||
| Type | Designation | Function | For modules with | 
 | |||
| 
 | 
 | 
 | 
 | 
 | Order No. | 
 | |
| AE | Analog input | Acquisition of an analog signal via an analog input module channel (0 to 20 mA, | 6DS1  | 
 | |||
| 
 | 
 | 4 to 20 mA, 0 to ± 10 V; Pt 100 resistance thermometer, thermocouples) or an | 6DS1  | 
 | |||
| 
 | 
 | analog input module of the SIMATIC S5 programmable controllers (instrument | 6DS1  | 
 | |||
| 
 | 
 | range U) | 
 | ||||
| 
 | 
 | 6DS1  | 
 | ||||
| AR | Analog input allocation | Acquisition of 8 analog process variables, conversion into physical variables; | 
 | ||||
| 6DS1  | 
 | ||||||
| 
 | 
 | storage in GA blocks or direct linking | 6DS1  | 
 | |||
| AA | Analog output | Output of an analog signal via a channel of an analog output module or an ana- | 6DS1  | 
 | |||
| 
 | 
 | log output module of the SIMATIC S5 programmable controllers (instrument | 6DS1  | 
 | |||
| 
 | 
 | range U) | 
 | 
 | |||
| BEI | Binary input | Acquisition of binary signals via a binary input module; | 6DS1  | 
 | |||
| 
 | 
 | storage of binary signals in GB block | 6DS1  | 
 | |||
| BRA | Binary allocation | Acquisition of 8 binary signals via a binary input module; | 6DS1  | 
 | |||
| 
 | 
 | allocation of signals to specified linking addresses | 
 | 
 | |||
| 
 | BAU | Binary output | Output of up to 32 binary signals to a binary output module | 6DS1  | 
 | ||
| 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 6DS1  | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 6DS1  | 
 | 
| 
 | RZ | Input block for  | Acquisition of analog and binary signals from a channel of a  | 6DS1  | 
 | ||
| 
 | 
 | controller | troller module | 6DS1  | 
 | ||
| 
 | RZA | Output block for  | Transfer of the manipulated variable increment ΔY or setpoint increment ΔW | 
 | 
 | ||
| 
 | 
 | nel controller | from a  | 
 | 
 | ||
| 
 | BU8 | Binary transmitter monitor- | Acquisition and monitoring of 8 binary signals via a binary input module | 6DS1  | 
 | ||
| 
 | 
 | ing block | 
 | 
 | 
 | 6DS1  | 
 | 
| 
 | BU16 | Binary transmitter monitor- | Acquisition and monitoring of 16 binary signals via a binary input module | 6DS1  | 
 | ||
| 
 | 
 | ing block | 
 | 
 | 
 | 
 | 
 | 
| 
 | ZE | Metered pulse input | Acquisition of a channel of a metered pulse input module | 6DS1  | 
 | ||
| 
 | DR | Input/output for speed con- | Acquisition of signals from the interface module, and transfer of signals to the | 6DS1  | 
 | ||
| 
 | 
 | trollers | interface module | 
 | 
 | ||
| 
 | E110 | Binary input for SIMATIC | Reading in of 16 binary values from an interface module for input modules of | 6DS1  | 
 | ||
| 
 | 
 | S5 input modules | the SIMATIC  | 6DS1  | 
 | ||
| 
 | 
 | 
 | SIMATIC S5 programmable controllers (instrument range U) or for standard | 6DS1  | 
 | ||
| 
 | 
 | 
 | binary input modules | 6DS1  | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 6DS1  | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 6DS1  | 
 | 
| 
 | A110 | Binary output for SIMATIC | Output of 16 binary values from an interface module for output modules of the | 6DS1  | 
 | ||
| 
 | 
 | S5 output modules | SIMATIC  | 6DS1  | 
 | ||
| 
 | 
 | 
 | SIMATIC S5 programmable controllers (instrument range U) or for standard | 6DS1  | 
 | ||
| 
 | 
 | 
 | binary output modules | 6DS1  | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 6DS1  | 
 | 
| 
 | S5KE | Coupling to S5 | Acquisition of signals from the interface module via telegrams with  | 6DS1  | 
 | ||
| 
 | 
 | - receive | point coupling | 
 | 
 | ||
| 
 | S5KS | Coupling to S5 | Transfer of signals to the interface modules via telegrams with  | 6DS1  | 
 | ||
| 
 | 
 | - transmit | coupling | 
 | 
 | ||
| 
 | AEF | Analog input (field multi- | Driver for acquisition of analog signals via the field multiplexer analog input | 6DS1  | 
 | ||
| 
 | 
 | plexer) | modules 2) | 6DS1  | 
 | ||
| 
 | AAF | Analog output (field multi- | Driver for acquisition of analog signals via the field multiplexer analog output | 6DS1  | 
 | ||
| 
 | 
 | plexer) | modules 2) | 6DS1  | 
 | ||
| 
 | BEF | Binary input (field multi- | Driver for acquisition of binary signals via the binary signal input modules of the | 6DS1  | 
 | ||
| 
 | 
 | plexer) | field multiplexer and for acquisition of fault signals from the binary I/O modules | 6DS1  | 
 | ||
| 
 | 
 | 
 | of the field multiplexer 2) | 
 | 
 | ||
| 
 | BAF | Binary output (field multi- | Driver for output of binary signals via the binary signal output modules of the | 6DS1  | 
 | ||
| 
 | 
 | plexer) | field multiplexer 2) | 
 | 
 | ||
| 
 | PRA | Testable relay module | Driver for output of 16 binary signals to a testable relay output module | 6DS1  | 
 | ||
| 
 | PBE | Testable binary input | Acquisition of binary signals via a testable binary input module, and transfer of | 6DS1  | 
 | ||
| 
 | 
 | 
 | the binary signals to  | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
1)Coupling module
2)No longer available
| Siemens PLT 111 · 1999 | 2/7 | 