Automation systems

ES 100 K

Ordering data for ES 100 K

Ventilation roof

Ordering data

Order No.

ES 100 K extension

6DS2 103 -

820 760

15 U

 

 

15

600 x 360

 

 

 

 

630

1 U = 44.5 mm

 

702

10.2

29

 

 

 

Æ

 

 

 

40

￿

system

 

Basic system

 

• Extension system AC 230 V

1 X X 0

• Extension system DC 24 V

2 X X 0

Housing

 

• Without housing

0

Sheet-steel housing, degree of

1

protection IP 21, without heat

 

exchanger

Order No.

 

ES 100 K options

 

Connection of the 1st of max. four ES 100 K systems

 

of a link to

 

 

- I/O bus 1(A), address range 0 to 60, or

 

- I/O bus 2(B), address range 100 to 160

 

2 interface modules for ES 100 K

6DS1 322-8AA

 

extension system

 

 

Can be inserted in slot for

 

 

I/O modules in the AS 235 and

 

￿ES 100 K

 

Fig. 3/10 ES 100 K extension system, design

Housing

The ES 100 K extension system is installed in a sheet-steel hous- ing with degree of protection IP 21. This corresponds to a stan- dard ordering configuration:

Cable for signal transmission

 

(max. length

Length 25 m

6ES5 721-0BC50

of a link:

5 m

6ES5 721-0BF00

500 m)

50 m

6ES5 721-0CF00

 

100 m

6ES5 721-0DB00

 

500 m

6ES5 721-0DF00

Intermediate lengths

See Catalog ST 50

Sheet-steel housing, degree of

protection IP 21C79451-A3260-A50 Dimensions (HxWxD)

820 mm x 600 mm x 360 mm, without heat exchanger, with

separate ventilation roof,

top panel with ventilation slits,

front door, 600 mm wide, with lock,

base with screwed-in cable panel,

175 mm deep, front half with ventilation slits

When using the supplied parts set for wall mounting, the dimen- sions are increased as shown in Fig. 3/10.

Cable terminating plug

6ES5 760-1AA11

Can be inserted in interface mod-

 

ule for ES 100 K, required with last

 

extension system of a link

 

In addition when using the

 

address range 100 to 160:

 

Interface module for I/O bus 2

6DS1 312-8BB

 

 

Connection of 2nd to 4th ES 100 K system

of a link

 

Required per ES 100 K system:

 

Interface module for ES 100 K

6DS1 322-8AA

extension system

 

Can be plugged in slot for I/O

 

modules of ES 100 K

 

Also refer to the ordering instructions in the appendix (page 8/2) with information on ordering complete systems and options.

Cable for signal transmission See above

Installation of ES 100 K in standard cabinet if cabinet messages are to be detected

Alarm logic module

6DS1 901-8AA

 

 

System documentation

 

 

 

Instruction Manual “ES 100 K

 

extension system” 1)

 

– German

C79000-B8000-C124

– English

C79000-B8076-C124

 

 

1)Only order separately if the ES 100 K system is not ordered together with an AS 235 K system.

3/22

Siemens PLT 111 · 1999

Page 46
Image 46
Siemens AS 235 appendix Ordering data for ES 100 K, ES 100 K extension, ES 100 K options