This catalog is out of date, see note on page 1
Automation systems
AS 235 H
Ordering data for basic cabinet
Ordering data | Order No. |
|
|
|
|
|
|
|
|
| Ordering data | Order No. |
|
|
|
|
|
|
|
|
|
|
|
| ||
AS 235 automation system, | 6DS2 131- |
|
|
|
|
|
|
| - |
| AS 235 H automation system, | 6DS2 131- |
|
| - |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
basic cabinet |
|
|
|
|
|
|
|
|
|
| basic cabinet |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Basic unit |
|
|
|
|
|
|
|
|
|
| Option: power supply and bus |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
• Without basic unit |
| 0 |
|
|
|
|
|
|
| components |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
• Basic unit 4 Mbyte, with |
| 7 |
|
|
|
|
|
|
| • Without components |
| 0 |
|
|
|
|
|
|
|
|
|
| ||||
I/O bus 1, redundant design |
|
|
|
|
|
|
|
|
|
| • Power supply unit DC 24 V, |
| 1 |
|
|
|
|
|
|
|
|
|
| |||
• Basic unit 4 Mbyte, with |
| 8 |
|
|
|
|
|
|
| for redundant or |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| basic unit |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
I/O bus 1, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
design |
|
|
|
|
|
|
|
|
|
| • Power supply unit DC 24 V |
| 2 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| and connection unit for |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Standard I/O devices |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| remote bus, |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
• Without standard I/O devices |
|
|
| X |
|
|
|
|
| for redundant basic unit |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
• Operation channel 1 with pro- |
|
|
|
|
|
|
|
|
|
| • Power supply unit DC 24 V |
| 3 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
cess operation and configuring |
|
|
|
|
|
|
|
|
|
| and connection unit |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
keyboards, for redundant basic |
|
|
|
|
|
|
|
|
|
| for redundant |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| unit |
|
|
|
|
|
|
|
|
|
|
| remote bus, |
|
|
|
|
|
|
|
|
|
|
|
|
|
| – Without process monitor |
|
|
| A |
|
|
|
|
|
| for redundant basic unit |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| – With process monitor |
|
|
| M |
|
|
|
|
|
| • Power supply unit DC 24 V |
| 4 |
|
|
|
|
|
|
|
|
|
| ||
| • Operation channels 1 and 2: |
|
|
|
|
|
|
|
|
|
|
| and connection unit for |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 process operation keyboards |
|
|
|
|
|
|
|
|
|
|
| remote bus, |
|
|
|
|
|
|
|
|
|
|
|
|
|
| and configuring keyboard, for |
|
|
|
|
|
|
|
|
|
|
| for |
|
|
|
|
|
|
|
|
|
|
|
|
|
| redundant basic unit |
|
|
|
|
|
|
|
|
|
|
| • Power supply unit DC 24 V |
| 5 |
|
|
|
|
|
|
|
|
|
| |
| – Without process monitors |
|
|
| C |
|
|
|
|
|
| and connection unit |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| – With 2 process monitors |
|
|
| N |
|
|
|
|
|
| for redundant |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| • Operation channel 1 with pro- |
|
|
|
|
|
|
|
|
|
|
| remote bus, |
|
|
|
|
|
|
|
|
|
|
|
|
|
| cess operation and configuring |
|
|
|
|
|
|
|
|
|
|
| for |
|
|
|
|
|
|
|
|
|
|
|
|
|
| keyboards, for |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Option: |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| basic unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| – Without process monitor |
|
|
| E |
|
|
|
|
|
| system cabinets |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| – With process monitor |
|
|
| P |
|
|
|
|
|
| • Standard cabinet, degree of |
| 1 |
|
|
|
|
|
|
|
| ||||
| • Operation channels 1 and 2, |
|
|
|
|
|
|
|
|
|
|
| protection IP 20, 400 mm deep, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 2 process operation keyboards |
|
|
|
|
|
|
|
|
|
|
| without heat exchanger |
|
|
|
|
|
|
|
|
|
|
|
|
|
| and configuring keyboard, for |
|
|
|
|
|
|
|
|
|
|
| • Standard cabinet, degree of |
| 2 |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| protection IP 54, 600 mm deep, |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| – Without process monitors |
|
|
|
|
|
|
|
|
|
|
| with heat exchanger |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| – With 2 process monitors |
|
|
| G |
|
|
|
|
|
| • Standard cabinet, degree of |
| 3 |
|
|
|
|
|
|
|
| ||||
|
|
|
|
| Q |
|
|
|
|
|
| protection IP 20, 600 mm deep, |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Option: |
|
|
|
|
|
|
|
|
|
|
| without heat exchanger |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| extension units |
|
|
|
|
|
|
|
|
|
|
| Option: |
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Without extension unit |
|
|
|
|
| X |
|
| system documentation |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| • Extension unit EE1, |
|
|
|
|
| A |
|
|
|
| • Without system documentation |
|
|
|
|
|
| 0 | X |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| • German documentation |
|
|
|
|
|
| 0 | D |
| |||||
| • Extension unit EE1, |
|
|
|
|
| B |
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| • English documentation |
|
|
|
|
|
|
| 0 E |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| • Extension units EE1 and EE2, |
|
|
|
|
| C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| • Extension units EE1 and EE2, |
|
|
|
|
| D |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| • Extension units EE1, EE2 and |
|
|
|
|
| E |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EE3, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Extension units EE1, EE2 and |
|
|
|
|
| F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EE3, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Also refer to the ordering instructions in the appendix (page 8/2) with information on ordering complete systems and options.
3/14 | Siemens PLT 111 · 1999 |