Automation systems

AS 235

Ordering data for basic cabinet

With the standard ordering configuration, an additional connec- tion unit for a single or redundant remote bus can be selected under “Power supply and bus components” in addition to the power supply unit. The connection unit comprises:

• Interface module for 20-m local bus N-AS

6DS1 223-8AC

• Bus converter UI

6DS4 400-8AB

(2 x with redundant remote bus)

 

• Connector board AF “Remote bus”

6DS9 203-8DA

(2 x with redundant remote bus)

 

• For single remote bus:

 

Connecting cable with 3 plugs for connection

6DS8 204-8LC

of N-AS to bus converter 1 and

 

connection distributor for 20-m local bus

 

• For redundant remote bus:

 

Connecting cable with 4 plugs for connection

6DS9 201-8CA

of N-AS to bus converters 1 and 2

 

and connection distributor for 20-m local bus

 

The appropriate remote bus cable is required in addition to an interface connection unit for single or redundant remote bus. This cable is connected to the connector board AF and links the individual participants together at distances up to 4 km.

Ordering data for remote bus cable: see Section 6.

System cabinets

￿

Ordering data

Order No.

 

 

 

 

 

 

AS 235 automation system,

6DS2 124-

 

 

 

 

-

 

 

 

 

 

 

basic cabinet

 

 

 

 

 

 

 

Basic unit

 

 

 

 

 

 

 

• Without basic unit

 

0

 

 

 

 

• Basic unit 4 Mbyte,

 

7

 

 

 

 

wire-wrap system

 

 

 

 

 

 

 

• Basic unit 4 Mbyte,

 

8

 

 

 

 

Maxi-Termi-Point system

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard I/O devices

 

 

 

 

 

 

 

 

• Without standard I/O devices

 

 

 

X

 

 

• For operation channel 1:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

process operation/configuring

 

 

 

 

 

 

 

 

keyboards, mini floppy disk unit

 

 

 

 

 

 

 

 

– Without process monitor

 

 

 

A

 

 

 

– With process monitor

 

 

 

M

 

 

• Operation channel 2: 2 process

 

 

 

 

 

 

 

 

oper. keyboards, config. key-

 

 

 

 

 

 

 

 

board and mini floppy disk unit

 

 

 

 

 

 

 

 

– Without process monitor

 

 

 

C

 

 

 

– With 2 process monitors for

 

 

 

N

 

 

operation channels 1 and 2

 

 

 

 

 

 

 

The system cabinets (see page 3/23 for further information) are supplied with 2 cabinet lamps and test pushbuttons and consist of the following components:

• Standard cabinet

 

– IP 20, 2200 x 900 x 400

6DS9 300-8AA

– IP 54, 2200 x 900 x 600

6DS9 310-8AB

– IP 20, 2200 x 900 x 600

6DS9 302-8AA

• Transport lugs (4 off)

6DS9 906-8CA

• Cable set for connection of cabinet lamp

6DS9 912-8AA

• Door contact with mounting parts and

C79165-A3012-D83

connection cables

 

• Cable duct, horizontal, for I/O bus

6DS9 906-8PA

• Cable duct, vertical

C79165-A3012-D51

• Parts kit (screen board)

C79165-A3012-D41

• Thermostats, wired

C79165-A3012-D81

• Cable with mounting parts

C79165-A3012-D129

• Cable clamping rail

C79165-A3012-D128

The standard cabinet IP 54 with heat exchanger is supplied with the following additional components:

• Power distribution subrack AC 230 V

6DS4 408-8AA

with line filter

 

• Cable for monitoring the

C79195-A3828-H230

heat exchanger

 

• Cable for connection of line filter

C79195-A3205-B93

to motor supply terminals

 

Side panels or partitions for the standard cabinets: see cabinet accessories on page 3/23.

System documentation

German or English system documentation can be ordered with the AS 235 basic cabinet. The documentation comprises:

• Manuals

 

– “AS 235 automation system”

C79000-G8000-C295

– “Function modules”, volumes 1 and 2

C79000-G8000-C30

– “Signal modules”

C79000-G8000-C31

– “Coupling and calculation modules”

C79000-G8000-C32

– “CS 275 bus system”

C79000-G8000-C6

• Description “AS 235, AS 235 H and AS 235 K

C79000-G8000-C416

automation systems, version G”,

 

volumes 1 to 3

 

• Manual “Notes and guidelines for

C79000-G8000-C417

planning, installation and operation”

 

In the English system documentation, the center block of the individual Order Nos. is replaced by “.....-G8076-...”.

AS 235 / AS 235 H / AS 235 K table pamphlet, C79000-N8000-C1 German, order separately if required.

Also refer to the ordering instructions in the appendix (page 8/2) with information on ordering complete systems and options.

Option:

 

 

 

 

 

 

 

 

extension units

 

 

 

 

 

 

 

 

• Without extension unit

 

X

 

 

 

 

 

 

• Extension unit EE1,

 

A

 

 

 

 

 

 

wire-wrap system

 

 

 

 

 

 

 

 

• Extension unit EE1,

 

B

 

 

 

 

 

 

Maxi-Termi-Point system

 

 

 

 

 

 

 

 

• Extension units EE1

 

C

 

 

 

 

 

 

and EE2,

 

 

 

 

 

 

 

 

wire-wrap system

 

 

 

 

 

 

 

 

• Extension units EE1

 

D

 

 

 

 

 

 

and EE2,

 

 

 

 

 

 

 

 

Maxi-Termi-Point system

 

 

 

 

 

 

 

 

• Extension units EE1,

 

E

 

 

 

 

 

 

EE2 and EE3,

 

 

 

 

 

 

 

 

wire-wrap system

 

 

 

 

 

 

 

 

• Extension units EE1,

 

F

 

 

 

 

 

 

EE2 and EE3,

 

 

 

 

 

 

 

 

Maxi-Termi-Point system

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option: power supply and bus

 

 

 

 

 

 

 

 

components

 

 

 

 

 

 

 

 

• Without components

0

 

 

 

 

 

• Power supply unit DC 24 V

1

 

 

 

 

 

for single supply

 

 

 

 

 

 

 

 

• Power supply unit DC 24 V

2

 

 

 

 

 

for single supply and

 

 

 

 

 

 

 

 

connection unit for remote bus

 

 

 

 

 

 

 

 

• Power supply unit DC 24 V

3

 

 

 

 

 

for single supply and

 

 

 

 

 

 

 

 

connection unit for redundant

 

 

 

 

 

 

 

 

remote bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option:

 

 

 

 

 

 

 

 

system cabinets

 

 

 

 

 

 

 

 

• Without cabinet

0

 

 

 

 

• Standard cabinet, 400 mm

1

 

 

 

 

deep, degree of protection

 

 

 

 

 

 

 

 

IP 20, without heat exchanger

 

 

 

 

 

 

 

 

• Standard cabinet, 600 mm

2

 

 

 

 

deep, degree of protection

 

 

 

 

 

 

 

 

IP 54, with heat exchanger

 

 

 

 

 

 

 

 

• Standard cabinet, 600 mm

3

 

 

 

 

deep, degree of protection

 

 

 

 

 

 

 

 

IP 20, without heat exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option:

 

 

 

 

 

 

 

 

System documentation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Without system documentation

 

 

 

 

 

0 X

• German documentation

 

 

 

 

0

D

• English documentation

 

 

 

 

0

E

 

 

 

 

 

 

 

 

 

3/6