Jenn-Air JXT8142ADS, JXT8136ADS specifications INSTALLATION6, Installation

Page 7

INSTALLATION6

INSTALLATION

Add Blockings

Front

Support Bracket

Rear

Front

Dimensions of Support Arms 23.25”

rear

front

Support Arms with

Tabs position

Fasten Ceiling Plate

Fasten Support Frame

Mounting the Range Hood

1.Add and secure blockings (minimum 2x4 studs) onto ceiling joist.

2.Center, mark and fasten Ceiling Plate onto ceiling where hood is to be hung. Make sure front of bracket is facing as shown on diagram.

3.Determine height of hood, measure and attach four support arms onto blower unit with screws provided; use predrilled holes on blower unit and support arms. Make sure tabs on top of the arms are facing out for the front, and sideways for the rear, as shown on diagram. Attach support “U” bracket.

4.Slide telescopic duct covers onto the top of the blower unit.

5.Attach duct work to the ceiling and position the electrical.

6.Lift blower unit and fasten to Ceiling Plate (lock tabs on support frame into slots on CeilingPlate); secure support frame to Ceiling Plate with screws provided.

7.Connect duct work and electrical to the blower unit. (slide duct covers up to gain access to the top of the blower unit).

Image 7
Contents Installation Important Safety Notice Installation GuideList of Materials If turns or transitions are required INSTALLATION3Mounting Heights & Clearance DuctingINSTALLATION4 Specifications Electrical INSTALLATION5Cable Lock Installation INSTALLATION6Push telescopic duct section up in place and fasten INSTALLATION7Ductless Conversion INSTALLATION8Hotte DE Cuisinière Avis DE Sécurité Important Guide D’INSTALLATIONListe DES Matériaux Canalisation Hauteurs DE Montage ET DégagementAvertissement DE Risque D’INCENDIE Avertissement Caractéristiques Techniques Électricité AvertissementApposé sur le produit Verrou de câble Attachez le conduit au plafond et les composants élétriques Crochets de montage locking tabs Retirez les filtres métalliques de la hotte Réinstallez les filtres métalliquesTransformation EN Système DE Recyclage Filtres au charbon requisInstalacion Iimportante Aviso DE Seguridad Guia DE InstalacionLista DE Materiales Altura DE Montado Y Espacio Libre INSTALACION3Tuberia DE Extraccion Advertencia Peligro DE Incendio INSTALACION4Seguro de Cable INSTALACION5Especificaciones Instalacion Electrica AdvertenciaINSTALACION6 INSTALACION7 Vuelva a instalar los filtros de metal Cambiará de ,Exhaust Mode modo deINSTALACION8 Conversion SIN Tuberia DE Extraccion