Bloomfield 9010, 9016, 9012 Timer Adjustment, Remove Tank LID Assembly, Replace Thermostat

Page 15

SERVICING INSTRUCTIONS (continued)

601 75815 Owners Manual Integrity Decanter Brewers

TIMER ADJUSTMENT

The amount of water dispensed automatically during a brew cycle is controlled by the timer.

Place empty decanter under brew chamber. Press BREW button. Brewer should dispense one decanter of water. To adjust amount:

Remove brew chamber and button plug. Adjust knob on timer; clockwise increases time. Run several cycles to check amount of water delivered. Replace button plug.

REMOVE TANK LID ASSEMBLY

Unplug brewer or turn circuit breaker OFF. Turn OFF water supply. Remove top panel. Pull vent tube and inlet elbow out of basin pan.

Pull water inlet tube out of basin pan. Remove basin pan.

On models with faucet, disconnect inlet pipe at faucet shut-off valve and outlet pipe at faucet.

Disconnect all wiring from thermostat, hi-limit, and heating element.

Loosen center screw on tank hold-down bracket. Remove hold-down bracket by sliding short slotted end off of locking stud and lifting it off. Remove cover assembly by lifting it straight up.

Reassemble in reverse order.

REPLACE THERMOSTAT

Unplug brewer or turn circuit breaker OFF. Turn OFF water supply. Remove top panel.

Disconnect all wiring from thermostat only. Loosen and free jam nut from pass-thru fitting securing temperature sensing bulb. Remove two screws holding thermostat to bracket.

Lift out thermostat, sensing bulb and thermostat gasket.

Push sensing bulb into tank lid thermowell until fitting seats. Tighten capillary lock nut only enough to ensure no water leakage. Excessive tightening is not necessary.

Reassemble in reverse order.

IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure.

If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line.

IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid.

DO NOT OVER-TIGHTEN.

IMPORTANT:

If mounting thermostat

p/n 8512-51, be sure to place a new seal washer below the fitting on the capillary line.

If replacing gray-bodied thermo with p/n 8512-51, be sure to remove tube from thermowell.

13

Image 15
Contents Integrity Shipping Damage Claims Procedure Warranty StatementSpecifications Table of ContentsFeatures & Operating Controls Features and Operating ControlsAgency Approval Information Precautions and General InformationInstallation Instructions PLUMBER’S Installation InstructionsLeveling the Unit ELECTRICIAN’S Installation Instructions Installation InstructionsSTART-UP OperationPOUR-OVER Feature Automatic OperationHOT Water Faucet Brewing Coffee PreparationPOUR-OVER Operation Cleaning Instructions Procedure Clean Coffee BrewerSymptom Possible Cause Suggested Remedy Troubleshooting SuggestionsServicing Instructions Access PanelsTemp Temperature AdjustmentTimer Adjustment Remove Tank LID AssemblyReplace Thermostat Clean Solenoid Screen Replace Heating ElementReplace Solenoid Replace Timer Assembly Replace HOT Water Faucet CoilRepair HOT Water Faucet Procedure Delime the Water Tank Servicing Instructions Description Used on HOT Water Tank AssemblyCabinet Plumbing Components Formed TUBE, Faucet Coil Inlet AssemblyALT Electrical Components126 Cabinet ComponentsModel Wiring DiagramsWiring Diagrams Genuin e Parts

9012, 9016, 9010 specifications

Bloomfield has made a significant mark in the world of precision machining with its innovative series of machines, particularly the Bloomfield 9010, 9012, and 9016 models. These machines embody the advanced engineering principles and cutting-edge technologies that Bloomfield is known for, making them ideal for a variety of applications across different industries.

The Bloomfield 9010 is a versatile platform known for its robust construction and high-speed capabilities. It features a powerful spindle motor that allows for increased torque and faster operational speeds, ensuring efficient machining processes. This machine is designed with user-friendly software that streamlines the programming and command procedures, making it accessible for operators of varying skill levels. Its enhanced cooling system contributes to improved precision by maintaining optimal temperatures during operation, ensuring that thermal expansion does not compromise work quality.

The Bloomfield 9012 extends the functional capabilities of its predecessor with additional features that cater to more complex machining tasks. It integrates advanced automation technologies that allow for seamless integration into existing production lines. The 9012 machine comes equipped with multi-axis machining capabilities, which enable it to perform intricate geometries with high accuracy. Furthermore, the machine's tooling system is designed to accommodate a wide range of cutting tools, enhancing its adaptability for different materials and specifications.

Lastly, the Bloomfield 9016 takes precision machining to the next level with its state-of-the-art features. This model boasts an intelligent feedback system that constantly monitors the machining process, making real-time adjustments to enhance precision and reduce waste. The 9016 is also designed with a modular architecture that allows users to customize the machine according to their specific needs, making it a flexible option for both small and large manufacturing operations. With advanced safety systems in place, operators can work confidently, knowing that the machine is designed to protect against potential mishaps.

In summary, the Bloomfield 9010, 9012, and 9016 models represent the pinnacle of precision machining technology. They are built for performance, versatility, and user convenience, making them suitable for a wide range of industrial applications. From high-speed operations to complex multi-axis machining, these machines are engineered to meet the evolving demands of modern manufacturing environments.