SERVICING INSTRUCTIONS (continued)
622 75854 Owners Manual Gourmet 1000 Airpot/Thermal
TIMER ADJUSTMENT (AUTOMATIC BREWERS ONLY)
The amount of water dispensed automatically during a brew cycle is controlled by the timer.
Place empty airpot or thermal server under brew chamber. Press BREW button. Brewer should dispense one container of water. To adjust amount:
Remove brew chamber and button plug. Adjust knob on timer; clockwise increases time. Run several cycles to check amount of water delivered. Replace button plug.
REMOVE TANK LID ASSEMBLY
Unplug brewer or turn circuit breaker OFF. Turn OFF water supply. Remove top panel. Pull vent tube and inlet elbow out of basin pan.
On automatic models, pull water inlet tube out of basin pan. Remove basin pan.
On models with faucet, disconnect inlet pipe at faucet
Disconnect all wiring from thermostat,
Loosen center screw on tank
Reassemble in reverse order.
REPLACE THERMOSTAT
Unplug brewer or turn circuit breaker OFF. Turn OFF water supply. Remove top panel.
Disconnect all wiring from thermostat only. Loosen and free jam nut from
Lift out thermostat, sensing bulb and thermostat gasket. Reassemble in reverse order.
REPLACE HEATING ELEMENT
Remove tank lid assembly per above.
Remove two hex nuts holding element to cover. Pull element from mounting holes.
Reassemble in reverse order.
IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure.
If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line.
IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid.
DO NOT OVER-TIGHTEN.
IMPORTANT: When mounting thermostat, be sure a new seal washer is placed below the fitting on the capillary line. Push sensing bulb thru tank lid until fitting seats.
Tighten capillary lock nut only enough to ensure no water leakage. Excessive tightening is not necessary.
IMPORTANT: When replacing heating element, also replace seal gaskets.