SERVICING INSTRUCTIONS (continued)

REPLACE TIMER ASSEMBLY

622 75854 Owners Manual Gourmet 1000 Airpot/Thermal

Unplug power cord or turn circuit breaker OFF.

Remove front panel. Remove knob and three screws holding timer to bracket. Disconnect wiring to timer.

Reassemble in reverse order.

Adjust timer as described on page 13

REPLACE HOT WATER FAUCET COIL

Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.

Remove tank lid assembly per above.

Remove two hex nuts hot water coil to cover. Pull coil from mounting holes.

Reassemble in reverse order.

REPAIR HOT WATER FAUCET

Remove top panel and turn faucet valve OFF.

Unscrew aerator cap from faucet and remove handle retaining clip. Do not let faucet body turn.

Pull bonnet assembly from faucet body.

Examine the interior of the faucet body and the surface of the seat cup. Clean out any debris in the faucet body, using a stiff bristle brush if necessary.

Examine the aerator. Clean any debris from the screen or flow straightener, using a stiff bristle brush if necessary.

Reassemble in reverse order.

REPLACE BREW READY LIGHT or BREW BUTTON

Unplug power cord or turn circuit breaker OFF. Disconnect electric leads.

Using Switch Removal Tool (p/n 83209) or a thin screwdriver, compress mounting tabs then pry light or switch from mounting hole.

Reassemble in reverse order.

IMPORTANT: When replacing water faucet coil, also replace seal gaskets.

NOTE: Any abrasion or roughness on the flat end of the seat cup will require replacing the seat cup:

Work the seat cup out of the bonnet and off of the end of the stem.

Install a new seat cup, making sure the knob on the stem is fully inserted into the pocket of the seat cup, and the skirt of the seat cup is fully inserted into the bonnet.

15

Image 17
Contents 622 Shipping Damage Claims Procedure Warranty StatementSpecifications Table of ContentsFeatures and Operating Controls Agency Listing Information Precautions and General InformationLeveling the Unit Installation InstructionsPLUMBER’S Installation Instructions Automatic Brewers only Shock Hazard ELECTRICIAN’S Installation InstructionsSTART-UP OperationHOT Water Faucet POUR-OVER FeatureAutomatic Operation POUR-OVER Operation Brewing CoffeePreparation Cleaning Instructions Procedure Clean Coffee BrewerSymptom Possible Cause Suggested Remedy Troubleshooting SuggestionsServicing Instructions Access PanelsServicing Instructions Temperature AdjustmentRemove Tank LID Assembly Timer Adjustment Automatic Brewers onlyReplace Thermostat Replace Heating ElementReplace Solenoid Remove Faucet Supply from SolenoidRepair HOT Water Faucet Replace Timer AssemblyReplace HOT Water Faucet Coil Procedure Delime the Water Tank Servicing Instructions HOT Water Tank Assembly Exploded View & Parts ListSolenoid Repair Kits Electrical ComponentsFaucet Repair Kits Internal Plumbing ComponentsCabinet Components Wiring Diagram Wiring Diagram Telephone Fax