SERVICING INSTRUCTIONS (continued)

CAUTION -

CHEMICAL BURN

HAZARD

Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure.

Never siphon deliming chemicals or solutions by mouth.

This operation should only be performed by qualified and ex- perienced service personnel.

IMPORTANT: DO NOT spill, splash or pour water or deliming solution into or over any internal component other than the inside of the water tank.

IMPORTANT: DO NOT allow any internal components to come into contact with the deliming solution. Take care to keep all internal components dry.

NOTE: Repeat steps 4 thru 5 as required to remove all scale and lime build-up.

PROCEDURE: Delime the Water Tank

PRECAUTIONS:

Disconnect brewer from electric power.

 

Allow brewer to cool.

FREQUENCY:

As required (Brewer slow to heat)

TOOLS:

Deliming Solution

 

Protective Gloves, Goggles & Apron

 

Mild Detergent, Clean Soft Cloth or Sponge

 

Bristle Brush, Bottle Brush

 

Large Sink (or other appropriate work area)

1.Disconnect brewer from the electrical supply. For automatic brewers, turn off the water shut-off valve and disconnect the water supply line from the brewer inlet fitting.

2.Remove the tank lid assembly as described on page 13.

3.Remove the water tank from the brewer body by lifting straight up. Empty all water from the tank. Set the tank back into the brewer.

4.Mix 2 quarts of deliming solution according to the manufacturer’s directions. Carefully pour the deliming solution into the water tank. Lower the lid assembly back onto the tank. Allow to sit for 30 minutes, or as directed by the manufacturer.

5.At end of soaking period, remove lid assembly from tank. Thoroughly rinse internal components of lid assembly with clear water. Using a stiff bristle brush, scrub the heating element (and faucet water coil on automatic brewers) to remove lime and calcium build-up. Rinse with clean water. Store lid assembly in a safe location .

6.Remove the tank from the brewer and empty. Using a stiff bristle brush, scrub the interior of the water tank to remove lime and calcium build-up. Rinse with clean water.

625 75873 Owners Manual Gourmet 1000 Dual Airpot Brewers

16

Image 18
Contents 625 Warranty Statement Shipping Damage Claims ProcedureModel Volts Watts Amps Power Supply Requirements Table of ContentsSpecifications Wire + GroundFeatures and Operating Controls Features & Operating ControlsPrecautions and General Information Agency Listing InformationInstallation Instructions PLUMBER’S Installation InstructionsLeveling the Unit Installation Instructions ELECTRICIAN’S Installation InstructionsOperation START-UPPOUR-OVER Feature Automatic OperationHOT Water Faucet Right Side Brewing Coffee PreparationPOUR-OVER Operation Procedure Clean Coffee Brewer Cleaning InstructionsTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyAccess Panels Servicing InstructionsTemperature Adjustment Servicing InstructionsReplace Thermostat Timer Adjustment Automatic Brewers onlyRemove Tank LID Assembly Replace Heating ElementClean Solenoid Screen Replace SolenoidReplace Timer Assembly Replace HOT Water Faucet CoilRepair HOT Water Faucet Procedure Delime the Water Tank Servicing Instructions HOT Water Tank Assembly Description Used onElectrical Components Solenoid Repair KitsPlumbing Components Faucet Repair KitsCabinet Components Wiring Diagram Page Telephone Fax