INSTALLATION

Water Inlet Connection:

This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction. In addition:

1.A quick disconnect water connection or enough extra coiled tubing (at least 2 times the depth of the unit) so that the machine can be moved for cleaning underneath.

2.An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.

The JAVA2-QB-D is equipped with a 1/4" Flare Water Inlet Fitting, located behind the unit near the bottom.

HIGHLY RECOMMENDED:

A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/Phosphate Filter, to remove odors and inhibit lime and scale build up in the machine. Note: In areas with extremely hard water, a water softener must be installed in order to prevent a malfunctioning of the equipment and in order not to void the warranty.

STARTUP PROCEDURE

Caution: Make sure that the Heater Switch, located behind unit near the bottom, is in the OFF (toggle down) position.

1.Connect the 1/4" Dia. copper waterline to the 1/4" flare water inlet fitting of the valve.

2.Connect the power cord into a proper receptacle.

3.Activate the Power Switch (Toggle Up). The tank will start filling. Allow approximately 5 minutes for the tank to fill.

4.Activate the Heater Switch. Allow approximately 20-45minutes for the water to reach a preset temperature of 200°F. The heat up time will depend on the water inlet temperature, the input voltage, and the wattage of the elements in the machine.

5.Place cup under nozzle and press dispense switch, button will light while dispensing. The machine will dispense water at the rate of 1.3 oz. per second.

Repeat it several times for each dispense switch to check for consistent output.

6.While the tank is heating up, remove the hoppers, load them with products and reposition them back in the machine.

NOTE: Decanter capacity is up to 54 OZ. Cup capacity is up to 12 OZ.