Cecilware JAVA 2-QB-DC, JAVA 2-QB-D2, JAVA 2-QB-D3, JAVA 2-QB-D1 Programming for Automatic Dispense

Page 5

PROGRAMMING FOR AUTOMATIC DISPENSE

(See Door diagram)

1.Turn Power Switch ON (toggle switch inside door).

2.PRESS and HOLD [red] STOP Button with one hand.

3.PRESS and HOLD [green] DISPENSE Button with other hand.

4.RELEASE [red] STOP Button ONLY.

5.Continue to HOLD [green] DISPENSE Button until BUZZER sounds, then RELEASE.

6.PRESS and RELEASE [green] DISPENSE Button. Product begins dispensing.

When it reaches the “DESIRED VOLUME”,

7.PRESS and RELEASE [green] DISPENSE Button to SET “DESIRED VOLUME”.

DISPENSE Button can be jogged to top off.

8.PRESS and HOLD [red] STOP Button for 5 Secs. to LOCK IN “DESIRED VOLUME”.

Repeat steps 1 to 8 for each Dispense Button.

READY LIGHT

 

HEATING LIGHT

 

 

 

DISPENSE BUTTONS

The Automatic Dispense Buttons are factory programmed to dispense 1.3 oz. of water per second.

POWERSWITCH RINSE/ SERVESWITCH NOTE: Set programming for Cup Volume with cup shelf “DOWN”.

Set programming for Decanter Volume with cup shelf “UP”.

PRODUCT STRENGTH ADJUSTMENTS:

The JAVA 2-QBD units have variable speed control auger motors with variable speed of 10 to 30 RPM.

Drink or Product Strength can be changed by adjusting the

Gram Throw Dial on inside door panel.

The Gram Throw is factory preset at approx. 2.2 gr. per 8 oz. cup and 15.0 gr. per decanter.

The water flow rate adjustment for the dispense valve should remain fixed at 1.3 oz per sec.

DRINK

STRENGTH

ADJUSTMENT

PROGRAMMI NG INSTRUCTION

Page 4

Image 5
Contents Page Page Page Installation Programming for Automatic Dispense Rinse Chambers Page Page Overflow Drain Water Inlet Auger Motor CD151 83 RPM Parts List Java 2-QB-D, -D1, -D2, -D3, -DC Optional Optional Programming SW. CUP/ Decanter Power Teach ME