Honeywell STR94G, STR93D Communication Options, Indicating Meter Options, Remote Seal Options

Page 23

34-ST-03-57 Page 23

 

 

 

STR9xx

 

 

 

 

 

 

 

TABLE III - OPTIONS

Selection

 

3D

 

4G

 

 

 

 

None

 

 

00

 

 

 

 

 

Communication Options

 

 

 

 

 

 

 

 

HART

5.x

Protocol Compatible Electronics

HC

 

e

 

e

 

HART

6.x

Protocol Compatible Electronics

H6

 

e

 

e

 

FOUNDATION Fieldbus Communications

FF

 

r

 

 

r

 

Indicating Meter Options

 

 

 

 

 

 

Analog Meter (0-100 Even 0-10 Square Root)

ME

 

 

 

 

Smart Meter

SM

 

 

 

 

Custom Configuration of Smart Meter

CI

 

m

 

m

 

Local Zero

 

LZ

 

x

 

x

 

Local Zero and Span

ZS

 

s

 

s

 

Transmitter Housing & Electronics Options

 

 

 

 

 

 

 

 

NAMUR Failsafe Software

NE

 

15

 

15

 

SIL 2 - TÜV Certified transmitter (requires HC and WP options)

SL

 

14

 

14

 

Lightning Protection

LP

 

 

 

 

Custom Calibration and I.D. in Memory

CC

 

 

 

 

Transmitter Configuration

TC

 

 

 

 

Write Protection (Delivered in the "enabled" position)

WP

 

 

 

 

Write Protection (Delivered in the "disabled" position)

WX

 

 

 

 

316 SS Electronics Housing - with M20 Conduit Connections

SH

 

n

 

n

 

1/2" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC)

A1

 

n

 

n

 

1/2" NPT to 3/4" NPT 316 SS Conduit Adapter

A2

 

u

 

u

 

Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit

A3

 

i

 

 

i

 

Adapter (use for FM and CSA Approvals)

 

 

 

 

 

 

Stainless Steel Customer Wired-On Tag

TG

 

 

 

 

(4 lines, 28 characters per line, customer supplied information)

 

 

 

 

 

 

Stainless Steel Customer Wired-On Tag (blank)

TB

 

 

 

 

End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)

SP

 

a

 

a

 

End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)

PG

 

a

 

a

 

End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)

TL

 

a

 

a

 

End Cap Live Circuit Warning Label in German (only with ATEX 3D)

GE

 

a

 

a

 

Meter Body Options (Seal bolt material depends on Transmitter bolt material)

 

 

 

 

 

 

 

A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads

CR

 

 

 

 

 

316 SS Bolts and 316 SS Nuts for Process Heads

SS

 

 

 

 

 

B7M Bolts and Nuts for Process Heads

B7

 

 

 

 

 

Remote Seal Options

 

 

 

 

 

 

 

 

Gold Plated Seal Diaphragm (1 Seal)

G1

 

j

 

 

j

 

Gold Plated Seal Diaphragm (2 Seals)

G2

 

j

 

 

 

 

Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking

N1

 

j

 

 

j

 

Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking

N2

 

j

 

 

 

 

Transmitter Mounting Brackets Options

 

 

 

 

 

 

Mounting Bracket - Carbon Steel

MB

 

 

 

 

Mounting Bracket - 304 SS

SB

 

 

 

 

Flat Mounting Bracket

FB

 

 

 

 

Services/Certificates Options

UM

 

 

 

 

Users Manual Paper Copy (Standard, HC or FF ships accordingly)

 

 

 

 

Clean Transmitter & Seals for Oxygen or Chlorine Service with Certificate

0X

 

h

 

h

 

Over-Pressure Leak Test with F3392 Certificate

TP

 

 

 

 

Calibration Test Report and Certificate of Conformance (F3399)

F1

 

 

 

 

Certificate of Conformance (F3391)

F3

 

 

 

 

Certificate of Origin (F0195)

F5

 

 

 

 

FMEDA Certificate (SIL 1)

F6

 

 

 

 

NACE Certificate (F0198)

F7

 

o

 

 

 

NACE Certificate (F0198) for welded meter bodies only

F8

 

16

 

 

 

 

Marine Type Approvals (DNV, ABS, BV & LR)

MT

 

2

 

2

 

Warranty Options

 

 

 

 

 

 

Additional Warranty - 1 year

W1

 

 

 

 

Additional Warranty - 2 years

W2

 

 

 

 

Additional Warranty - 3 years

W3

 

 

 

 

Additional Warranty - 4 years

W4

 

 

 

 

Table III continued next page

b

b

b

b

b

b

b

b

b

b

b

Image 23
Contents Introduction Guide34-ST-03-57 Description of Diaphragm SealsStainless Steel Nipples are available Description FeaturesOperating Conditions All Models Silicone DC200 CtfeMbar ParameterDescription BarParameter Description Performance Under Rated Conditions General for all ModelsNon-Sparking, Zone Physical and Approval BodiesIntrinsically Safe, Zone 0/1 EEx ia IIC T4, T5, T6 97/23/EC 34-ST-03-57 Parameter DescriptionApplication Data Density, direct acting transmitter configuration Inches 34-ST-03-57 Reference DimensionsmillimetersSTR94G LGP/I Remote Seal with Vertical Pipe Mount Options Avail InstructionsKey Number DescriptionDIN DN80-PN40 ST-03-57 Table II SealsSpec. Figure Wetted Material Hastelloy C Monel Tantalum Ansi Class 150/300/600 GFA Table II Seals Bolt SelectionCommunication Options Transmitter Housing & Electronics OptionsServices/Certificates Options Warranty OptionsApproval Type Location or Classification Selection Body Table III OptionsRestriction Available Only With Not Available With Letter RestrictionsRestrictions 21a Flush Flanged Seal Dimensions and drawingsDimensions and drawings, Dimensions and drawings, Dimensions and drawings, Dimensions and drawings, HART* is a trademark of the Hart Communication Foundation

STR94G, STR93D specifications

The Honeywell STR93D and STR94G are advanced temperature controllers designed for precision temperature management in a variety of applications, from industrial processes to HVAC systems. These intelligent devices are engineered to enhance efficiency, reliability, and user flexibility, catering to both simple and complex control scenarios.

The STR93D is characterized by its dual-channel capability, making it ideal for processes requiring simultaneous temperature monitoring and control. Its robust design ensures stable performance even in demanding environments. The controller features a user-friendly interface that includes a large, backlit display, allowing operators to easily navigate through menus and settings. The intuitive design simplifies the setup process, reducing installation time and minimizing user error.

On the other hand, the STR94G takes automation a step further with its advanced features and connectivity options. This model is equipped with a comprehensive set of control algorithms, including PID, on-off, and fuzzy logic controls, ensuring precise temperature regulation. The STR94G also supports multiple input types, such as thermocouples and RTDs, providing versatility across various applications.

Both models incorporate Honeywell's proprietary Smart Control technology, which optimizes energy consumption and enhances operational efficiency. This technology not only ensures accurate temperature management but also contributes to reduced operational costs by minimizing energy waste. Additionally, the controllers support communication protocols such as Modbus and BACnet, facilitating easy integration into existing systems and enabling remote monitoring capabilities.

Both controllers are built with durability in mind, featuring a rugged housing that protects against environmental factors, including dust and moisture. This makes them suitable for use in harsh industrial settings as well as in less demanding environments. Their adaptability and advanced technology provide users with solutions that not only meet but exceed industry standards.

In summary, the Honeywell STR93D and STR94G are exemplary temperature controllers that stand out in their field. They combine advanced control features, robust design, and exceptional connectivity, making them suitable for a wide range of applications. Whether for industrial use or commercial HVAC installations, these controllers deliver reliability and efficiency, setting a benchmark in temperature control solutions.