Honeywell STR94G, STR93D Restrictions, Restriction Available Only With Not Available With Letter

Page 25

34-ST-03-57 Page 25

RESTRICTIONS

Restriction

 

Available Only With

 

Not Available With

Letter

Table

Selection

Table

Selection

a

III

3D or 3H

 

 

b

 

Select only one option

from this group

 

 

 

 

_ _ _ _ _ _ BF _ _ _ _,

 

 

 

 

_ _ _ _ _ _ BG _ _ _ _,

c

 

 

II

_ _ _ _ _ _ BH _ _ _ _,

 

 

 

 

_ _ _ _ _ _ JF _ _ _ _,

 

 

 

 

_ _ _ _ _ _ JG _ _ _ _,

 

 

_ _ _ _ _ _ BF _ _ _ _,

 

 

d

II

_ _ _ _ _ _ BG _ _ _ _,

 

 

_ _ _ _ _ _ JF _ _ _ _,

 

 

 

 

 

 

 

 

_ _ _ _ _ _ JG _ _ _ _,

 

 

e

 

 

III

4G

 

 

_ A _ _ _ _ _ _ _ _ _ _,

 

 

 

 

_ B _ _ _ _ _ _ _ _ _ _,

 

 

 

 

_ C _ _ _ _ _ _ _ _ _ _,

 

 

g

II

_ G _ _ _ _ _ _ _ _ _ _,

 

 

 

 

_ H _ _ _ _ _ _ _ _ _ _,

 

 

 

 

_ J _ _ _ _ _ _ _ _ _ _,

 

 

 

 

_ 2 _ _ _ _ _ _ _ _ _ _,

 

 

h

I, II

_ 2 _ - 2 _ _ _ _ _ _ _ _ _ _ _

 

 

i

III

1C or 2J

 

 

 

 

 

 

_ _ _ _ _ _ AF _ _ _ _

 

 

 

 

_ _ _ _ _ _ BF _ _ _ _

j

 

 

II

_ _ _ _ _ _ BG _ _ _ _

 

 

_ _ _ _ _ _ BH _ _ _ _

 

 

 

 

_ _ _ _ _ _ GG _ _ _ _

 

 

 

 

_ _ _ _ _ _ JF _ _ _ _

 

 

 

 

_ _ _ _ _ _ JG _ _ _ _

m

III

SM

 

 

n

 

 

III

1C, 2J

o

III

CR

 

 

 

 

 

 

DC704 and Syltherm 800

 

 

 

 

fills and close-couple require

 

 

 

 

SS seal upper.

 

 

 

 

_ _ _ BCA _ _ 5 _ _ _,

 

 

 

 

_ _ _ CAA _ _ 5 _ _ _,

 

 

 

 

_ _ _ CCA _ _ 5 _ _ _,

 

 

 

 

_ _ _ CCC _ _ 5 _ _ _,

p

 

 

II

_ _ _ DAA _ _ 5 _ _ _,

 

 

_ _ _ DCA _ _ 5 _ _ _,

 

 

 

 

 

 

 

 

_ _ _ DCC _ _ 5 _ _ _,

 

 

 

 

_ _ _ DGA _ _ 5 _ _ _,

 

 

 

 

_ _ _ DGC _ _ 5 _ _ _,

 

 

 

 

_ _ _ DDA _ _ 5 _ _ _,

 

 

 

 

_ _ _ _ _ _ GE _ _ _ _,

 

 

 

 

_ _ _ _ _ _ _ _ A _ _ _

 

 

 

 

_ _ _ _ _ _ _ _ B _ _ _

 

 

0 _ _ _ _ _ _ _ _ _ _ _ _,

 

 

q

II

2 _ _ _ _ _ _ _ _ _ _ _ _,

 

 

 

 

4 _ _ _ _ _ _ _ _ _ _ _ _

 

 

r

 

 

III

TC, ME, 4G, 3S

s

 

 

III

FF, ME

Restrictions continued next page

Image 25
Contents Introduction Guide34-ST-03-57 Description of Diaphragm SealsStainless Steel Nipples are available Description FeaturesOperating Conditions All Models Silicone DC200 CtfeDescription ParameterBar MbarParameter Description Performance Under Rated Conditions General for all ModelsIntrinsically Safe, Zone 0/1 EEx ia IIC T4, T5, T6 Physical and Approval BodiesNon-Sparking, Zone 97/23/EC 34-ST-03-57 Parameter DescriptionApplication Data Density, direct acting transmitter configuration Inches 34-ST-03-57 Reference DimensionsmillimetersSTR94G LGP/I Remote Seal with Vertical Pipe Mount Options Key Number InstructionsDescription AvailDIN DN80-PN40 Spec. Figure Table II SealsST-03-57 Wetted Material Hastelloy C Monel Tantalum Ansi Class 150/300/600 GFA Table II Seals Bolt SelectionServices/Certificates Options Transmitter Housing & Electronics OptionsWarranty Options Communication OptionsApproval Type Location or Classification Selection Body Table III OptionsRestriction Available Only With Not Available With Letter RestrictionsRestrictions 21a Flush Flanged Seal Dimensions and drawingsDimensions and drawings, Dimensions and drawings, Dimensions and drawings, Dimensions and drawings, HART* is a trademark of the Hart Communication Foundation