Warnings about building in the hob

lEnsure the eventual plastic covering of the furniture unit has been fixed with a heatproof adhesive (100°C heatproof).

lFitting of solid wood panel borders on the working top or behind the hob is allowed provided that minimum distances are observed.

lA insulation panel which can only be removed with tools must be fitted under the hob at a minimum distance of 50 mm.

lIf the hob must be installed beside a cupboard, ensure a minimum distance of 40 mm. is observed and the side of the cupboard is covered with heatproof material.

lBefore making the cut out in the worktop ensure that the edges of the hob that are to be near the rear wall have a minimum distance of 55 mm.

lA minimum distance of 100 mm. must be observed between the hob and an eventual side wall exceeding the working top height.

lHanging furniture units or cooker hoods must be fitted at a minimum height of 650 mm. from the hob.

lCombustible or not heatproof materials must be kept away from the appliance.

16

Image 16 Contents
DK-M Page Page Table of contents Safety information Description of the product How to use Control knob to the leftResidual-Heat indicator Pilot lightAdvice and hints for using the cooking zones Page Ceramic glass hob Cleaning and maintenanceStainless steel surfaces Tips on the use Ceramic hob unit No no YESDo not stare at the heating units when in operation Installation Electrical connection Page Building in Dimensions Cut Out Size Securing the hob into the cut out Technical data Servicing