Bosch Appliances 250 SXO LP, 250 SXO NG Special adjustment for measuring and adjusting CO2 levels

Page 27

Special adjustment for measuring and adjusting CO2 levels

9Special adjustment for measuring and adjusting CO2 levels

The CO2 can only be adjusted by a certified gas technician with a calibrated CO2 analyzer.

Caution: One factor that may affect CO2 levels is improper gas pressure. Please see Chapter 2.9 for the procedure to measure gas pressure and record your findings below:

Static Gas Pressure:

 

“ WC

P1 Operating Pressure:

 

“ WC

 

 

The P1 minimum operating pressure is 5" WC for Natural Gas and 11"WC for Propane. Do not proceed in adjusting CO2 until pressure has been verified to be at or above these levels, but not to exceed 14” WC.

A. Once Pressure is good

BTurn ON/OFF switch to the OFF (O) position.

BRemove plug by prying with a small flathead screwdriver. Fig. 35

BInsert CO2 analyzer probe into the measuring port on the front right of the vent cap at an angle. The tip of the probe should be inserted to the middle of the vent cap (approx 5" inserted).

Note: Vent cap must be in place in order to measure CO2.

Fig. 35

BWhile holding the Program (M) button, move the ON/ OFF switch to ON (I) position (see Fig. 36). As soon as ‘188’ flashes on the display, release the Program button. The display should now read P2.

B. Measuring CO2 (Cover Installed):

BOpen hot water taps to achieve a flow rate of at least 4 gallons per minute. (1 tub and 2 sinks should be sufficient).

BRecord the CO2 reading in P2 below. (Analyzer reading may take several minutes to stabilize).

BPress the button until P1 appears. Unit will ramp up to high fire and the flow should increase.

BRecord the CO2 reading in P1 on the next page.

P2 CO2 Reading:

 

% CO2

P1 CO2 Reading:

 

% CO2

 

Compare your readings to those found in table 1 under the “With Front Cover” column. If CO2 readings are off make adjustments as outlined below.

Note: The “Without Front Cover” column gives approximate values with the cover off to ease the adjustment process. Final readings should be taken with the cover on.

C. Adjusting CO2:

Note: P1 adjustment will change the P2 reading. Confirm the P1 value BEFORE adjusting the P2 level.

1. P1 CO2 level off:

BLoosen yellow painted Philips screw (1) and cover should rotate down (2) revealing a brass slotted screw. Fig. 37.

BAdjusting the slotted screw counter clockwise will

raise P1 CO2 levels and clockwise will lower P1 CO2 levels. Adjustments to the slotted screw will also change P2 CO2 levels.

2. P2 CO2 level off:

BRemove yellow painted #40 Torx cover from the front of the gas valve. (Fig. 38) A plastic #40 Torx screw will be revealed.

BAdjusting the plastic #40 Torx screw counter

clockwise will lower P2 CO2 levels and clockwise will raise P2 CO2 levels.

Note: These screw adjustment are very sensitive and may take several minutes to stabilize.

3.Verify both P1 and P2 are within the ranges specified in table 1 under the “With Front Cover” column. Repeat

steps 1 and 2 as necesssary until CO2 values are within the specified ranges.

Fig. 36

6 720 607 440

27

Image 27
Contents Electronic Ignition and built in Freeze protection SXO NG Natural Gas SXO LP Liquefied Petroleum LP GasFor exterior use only Index FCC Appliance details Features250 SXO Specifications Technical data On/Off and Temperature control switches Reset buttonSolar/preheat backup or high temperature booster use Unpacking the 250 SXO HeaterThis heater is packed securely. The box includes Dimensions Dimensions and Minimum installation clearancesGeneral rules to follow for safe operation Proper location for installing your heaterMounting installation Heater Placement and ClearancesVent Safety System Installation method of the mounting bracket willGAS Line Sizing Gas piping & connectionsFor Natural GAS For LP GASHigh Altitude Operation Measuring gas pressureWater connections Support all pipingOther than copper, we recommend that copper piping Operating instructions Electrical connectionsTo Turn OFF GAS to Appliance For your safety read before operating your water heaterLighting and operating instructions What to do if YOU Smell GASOperation instructions PowerTemperature selection Operation instructionsFlow/temperature charts Program button Use of remote control accessoryReset button OperationWater is TOO HOT Maintenance and serviceTroubleshooting Burners do not Ignite When HOT Water is Turned onLOW Water FLOW/PRESSURE TroubleshootingHOT Water Temperature Fluctuates / Unit Deactivated Temperature balance valvesCheck gas pressure. see chapter Troubleshooting Display Cause SolutionWhen the appliance starts up for some sec Onds and then looses ionization signalElectrical diagram Electrical diagramSXO Functional scheme SXO Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Components Diagram Components diagramDescription Reference Parts listSpecial adjustment for measuring and adjusting CO2 levels Special adjustment for measuring and adjusting CO2 levelsFinal Readings P2 CO2 Reading P1 CO2 Reading Protecting the environment Protecting the environmentSaving water resources Heat Exchanger Twelve Year Limited WarrantyTwelve Year Limited Warranty GeneralErial Number

250 SXO LP, 250 SXO NG specifications

Bosch Appliances has long been a trusted name in home appliances, and its 250 SXO NG and 250 SXO LP models are no exceptions. Designed with both innovation and user convenience in mind, these cooking appliances cater to a variety of culinary needs while ensuring high efficiency and performance.

The Bosch 250 SXO NG and 250 SXO LP are built to provide optimal cooking experiences. One of their main features is the powerful BTU output, which allows for efficient and even cooking across all burner configurations. This enables users to achieve restaurant-quality results right in their kitchen.

These models are equipped with precision flame control, which means that users can easily adjust the heat for delicate dishes or higher temperatures for rapid boiling. Such flexibility is essential for those who enjoy experimenting in the kitchen. Additionally, the 250 SXO LP and NG models come equipped with sealed burners that effectively contain spills and make cleaning a breeze.

Another highlight of these Bosch appliances is their consistent ignition system, designed to deliver reliable starts every time. This feature eliminates the frustration often associated with lighting gas-powered cooktops. The integrated safety measures further enhance peace of mind; with flame supervision devices to shut off the gas supply if the flame goes out, these appliances provide an added layer of security for users.

The Bosch 250 SXO models shine in design as well. Crafted with sleek stainless steel, they are not only reliable but also add a touch of modern elegance to any kitchen. The intuitive controls are user-friendly, allowing cooks of all skill levels to operate the appliance with ease.

Moreover, both models offer compatibility with a variety of cookware, making them suitable for everything from small saucepans to large stockpots. Energy efficiency is also a primary consideration, as these appliances are designed to minimize energy consumption without compromising on performance.

In summary, the Bosch Appliances 250 SXO NG and 250 SXO LP are exemplary cooking appliances that combine powerful performance with sophisticated design. With their advanced technologies and user-centric features, they stand out as reliable options for anyone looking to elevate their culinary adventures.