| Variety Steamer |
|
|
|
|
|
| Troubleshooting (continued) |
| |
|
|
|
|
Problem | Possible Cause | Corrective Action |
|
Unit heats but there is little | Insufficient or excessive calcium/mineral | Verify that a thin layer of calcium/mineral |
|
or no steam produced | buildup on generator surface. | deposits is present on the Generator sur- |
|
and/or |
| face. Refer to the Maintenance section of |
|
| this manual. |
| |
The product requires more | Black Manifold | Replace the Black Manifold |
|
steaming than usual. | or missing. | damaged, or missing. |
|
(Continued) | Low Generator temperature. | Verify Generator surface temperature is at |
|
| least 380° F (193° C), |
| |
|
|
| |
Steam leaks out of the | Black Manifold | Replace the Black Manifold |
|
sides of the unit. | missing. | damaged, or missing. |
|
Black Manifold is difficult | Black Manifold not being removed and | Remove and Clean the Black Manifold |
|
to remove or | cleaned daily as required. | Daily according to the Maintenance section |
|
onto the Generator. |
| of this manual. |
|
| Black Manifold | Replace the Black Manifold |
|
| worn. | aged or worn. |
|
| Black Manifold | Lubricate the Black Manifold |
|
| cated daily with Petro Gel. | according to the Maintenance section of |
|
|
| this manual. |
|
Unit floods over night | Solenoid valve is being held open by | Attempt to flush the debris out of the valve |
|
and/or continues to steam | debris from the building’s water line pip- | by operating the unit on a number of cycles |
|
even when just in ready | ing. | and then letting it rest. If the unit still |
|
mode. |
| leaks, contact your maintenance person or |
|
There is no |
| ||
| line just before the unit. | Authorized Service Agency. |
|
|
|
|
|
P/N 1010649 Rev. E 03/07 | 17 |