Panasonic FV-11-15VK1, FV-05-11VKS1, FV-05-11VK1 Practical Guide to Installation, Specifications

Page 12

PRACTICAL GUIDE TO INSTALLATION

Properly insulate the area around the fan to minimize building heat loss and gain. (Fig.20) Loose fill or batt insulation can be placed directly over the fan housing in the attic. Our fans and fan/light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor’s fan/light combination. Our efficient, cool-running motors and our LED lighting unit do not create enough ambient heat to be subjected to these limitations.

4 inches or 6 inches roof jack, wall cap, or soffit vent with backdraft damper

Mechanically connect duct to termination and seal with mastic or approved foil faced tape

2-3 ft straight run before elbow ln attic installation,

caulk box to drywall

Short piece of flexible duct helps

alignment and absorbs sound.

lnsulation

 

 

Clamps plus mastic or approved

Foil tape tightly covers all metal

Fig.20

foil faced tape at all flex joints

duct joints (glue PVC joints)

 

SPECIFICATIONS

Specifications for Base Model fans

 

Air

Voltage

Frequency

Duct

Air volume

Noise

Speed

Power

Weight

Model No.

diameter

at 0.1"WG

direction

(V)

(Hz)

(inches)

(CFM)

(sones)

(rpm)

(W)

Ib.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FV-05-11VKS1

Exhaust

 

 

 

50

<0.3

740

3.5

 

 

 

4 or 6

80

<0.3

795

5.5

10.6(4.8)

FV-05-11VK1

 

 

 

 

 

 

 

 

 

 

 

 

 

110

<0.3

915

9.5

 

 

 

 

 

 

 

 

 

 

 

 

110

<0.3

620

7.0

 

FV-11-15VK1

Exhaust

 

 

 

130

<0.3

630

10.0

10.6(4.8)

 

 

 

 

 

150

<0.3

660

13.0

 

HVI Certified performance based on HVI Procedures 915, 916, and 920.

Specifications for Multi Speed fans

 

Air

Voltage

Frequency

Duct

Air volume

Noise

Speed

Power

Weight

Model No.

diameter

at 0.1"WG

 

direction

(V)

(Hz)

(inches)

(CFM)

(sones)

(rpm)

(W)

Ib.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

<0.3

870

8.0

 

 

 

 

 

 

90

<0.3

835

6.5

 

FV-05-11VKS1,

 

 

 

 

80

<0.3

795

5.5

 

FV-05-11VK1

Exhaust

 

 

 

70

<0.3

760

4.3

10.6(4.8)

 

 

 

60

<0.3

745

3.6

(Plug-in

 

 

 

 

50

<0.3

740

3.5

 

FV-VS15VK1)

 

 

 

 

40

<0.3

730

2.7

 

 

 

 

 

 

30

<0.3

725

2.4

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

120

<0.3

625

7.4

 

 

 

 

 

 

110

<0.3

620

7.0

 

FV-11-15VK1

 

 

 

 

100

<0.3

615

5.6

 

 

 

 

 

90

<0.3

610

4.9

 

(Plug-in

Exhaust

 

 

 

80

<0.3

605

4.4

10.6(4.8)

FV-VS15VK1)

 

 

 

 

70

<0.3

600

3.8

 

 

 

 

 

 

60

<0.3

595

3.6

 

 

 

 

 

 

50

<0.3

590

3.1

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada).

Two Riverfront Plaza, Newark, NJ 07102

Panasonic corporation 2014

X0114-2024 15VK10420B

Image 12
Contents Model No. FV-05-11VKS1 FV-05-11VK1 FV-11-15VK1 For Your Safety Fig. B Please Read Prior to Installing this FAN DescriptionUnpacking Supplied Accessories DimensionsWiring Diagram Self-drilling ScrewFeature Indication Plug ‘N Play Function DevicesTurns the fan on for 20 minutes when either Motion Plug ‘N Play Function DevicesMotion or excess humidity is detected Installation Plug ‘N Play Function Devices Installation NEW ConstructionRemove the connector cover from position , 2 or 270 Installation Retrofit Disconnect power source before working on unit Practical Guide to Installation SpecificationsSpecifications for Base Model fans Two Riverfront Plaza, Newark, NJ

FV-05-11VK1, FV-05-11VKS1, FV-11-15VK1 specifications

Panasonic has established itself as a leader in the market for ventilation fans, and the FV-05-11VKS1, FV-05-11VK1, and FV-11-15VK1 models are prime examples of this commitment to quality and innovation. Designed primarily for residential use, these fans are engineered to enhance indoor air quality by effectively removing moisture and odors from bathrooms and other spaces.

The FV-05-11VKS1 model features a powerful, energy-efficient motor that operates at a low noise level, ensuring a peaceful environment while promoting ventilation. Its unique design involves a built-in pick-a-flow speed selector that allows users to choose between two airflow speeds—50 CFM and 80 CFM—providing flexibility based on personal needs and room specifications. This feature is particularly beneficial for homeowners who desire customized ventilation solutions.

On the other hand, the FV-05-11VK1 model also incorporates a similar motor and airflow options while emphasizing enhanced energy efficiency. With a quiet operating noise of only 0.3 sones at its low speed, it is one of the quietest fans in its class. This is critical for spaces like bathrooms where silence is often preferred. Additionally, the FV-05-11VK1 is equipped with a built-in damper system that helps prevent backdraft airflow, ensuring that conditioned air remains inside the home while outside air is effectively vented.

Lastly, the FV-11-15VK1 model showcases Panasonic's dedication to performance with its 150 CFM airflow capacity, making it suitable for larger rooms and higher moisture environments. This model retains the low noise level characteristic of its siblings, operating at 0.4 sones at low speed. It's an ideal choice for larger bathrooms or laundry rooms where increased ventilation is necessary to combat excessive humidity.

Across all three models, Panasonic employs its renowned ECM motor technology, which provides quicker and quieter operation while also ensuring the fans meet Energy Star standards. This commitment to energy efficiency not only saves utility costs but also reduces the carbon footprint of the household.

In summary, the Panasonic FV-05-11VKS1, FV-05-11VK1, and FV-11-15VK1 exhaust fans are designed with user-friendly features, advanced technologies, and superior characteristics that enhance indoor air quality while ensuring a quiet, efficient operation. Whether you are considering a replacement for an old fan or a new installation, Panasonic’s offerings are an excellent investment for maintaining a healthy home environment.