Panasonic FV-11-15VK1, FV-05-11VKS1, FV-05-11VK1 dimensions 270

Page 9

INSTALLATION (NEW CONSTRUCTION) CONTINUED

7.Refer to wiring diagram on page 5.

Follow all the local electrical safety codes as well as the National Electrical Code (NEC).

Using UL approved wire nuts, connect house power wires to ventilating fan wires. (Fig.5)

CAUTION

Mount junction box cover carefully so that lead wires are not pinched.

8.Insert fan body and slide into adapter assy with some strength, untill the flange overlaps the Flex-Z FastTM bracket. Secure the fan body to Flex-Z FastTM bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X6). (Fig.6)

CAUTION

Secure machine screw (M4X6) to the suitable hole and not touch the Flex-Z FastTM bracket. Please fix the screw carefully to avoid screw slip teeth.

9.Finish ceiling work. Ceiling hole should be aligned with the inside edge of the flange. (Fig.7)

10.Remove the tapes from louver and springs before installation. (Fig.8)

IMPORTANT:

Replace the sensor cover before the installation (only for plug-in Motion sensor modular FV-MSVK1). As shown below:

Keep on pressing the clasps when removing the ornamental cover.

Gloves

Ornamental cover

Insert the sensor cover (attachment for FV-MSVK1) into slot.

Sensor cover

11.Insert the grille mounting spring on the wiring side into the slot. (Fig.9)

12.Plug in the specified devices as your choice (refer to installation on page 8). Insert the motion sensor (FV-MSVK1 only) or LED night light (FV-NLVK1 only) into slot of the grille. Fix the lead wire into the clasp (Fig.9).

FV-05-11VKS1

Conduit Earth ground

FV-05-11VK1

FV-11-15VK1

to green

 

Wire nut

Junction

 

box

 

 

Netural to white

 

Two red wires

 

(Connect to a general

Live to black

manual wall switch)

 

 

 

Fig.5

Joist

 

 

Plug connector

 

 

 

Machine

 

 

screw

 

 

(M4X6)

 

Receptacle

2 Self-drilling

 

screws

Fig.6

 

10

1/2

(270)

Ceiling

Unit: inches (mm)

 

10

 

 

 

 

 

 

 

 

 

 

 

1/2

 

 

 

 

(270)

 

After finishing the ceiling job, fill gap between flange

and ceillng with caulk or other sealant to prevent air

leakage

 

Fig.7

 

 

 

 

Tapes

 

Fig.8

 

Clasp

Ceiling

 

Motion sensor

 

(FV-MSVK1 only)

LED night light

 

 

(FV-NLVK1 only)

 

Fig.9

9

Image 9
Contents Model No. FV-05-11VKS1 FV-05-11VK1 FV-11-15VK1 For Your Safety Fig. B Please Read Prior to Installing this FAN DescriptionUnpacking Dimensions Supplied AccessoriesWiring Diagram Self-drilling ScrewIndication Plug ‘N Play Function Devices FeatureTurns the fan on for 20 minutes when either Motion Plug ‘N Play Function DevicesMotion or excess humidity is detected Installation Plug ‘N Play Function Devices Installation NEW ConstructionRemove the connector cover from position , 2 or 270 Installation Retrofit Disconnect power source before working on unit Specifications Practical Guide to InstallationSpecifications for Base Model fans Two Riverfront Plaza, Newark, NJ

FV-05-11VK1, FV-05-11VKS1, FV-11-15VK1 specifications

Panasonic has established itself as a leader in the market for ventilation fans, and the FV-05-11VKS1, FV-05-11VK1, and FV-11-15VK1 models are prime examples of this commitment to quality and innovation. Designed primarily for residential use, these fans are engineered to enhance indoor air quality by effectively removing moisture and odors from bathrooms and other spaces.

The FV-05-11VKS1 model features a powerful, energy-efficient motor that operates at a low noise level, ensuring a peaceful environment while promoting ventilation. Its unique design involves a built-in pick-a-flow speed selector that allows users to choose between two airflow speeds—50 CFM and 80 CFM—providing flexibility based on personal needs and room specifications. This feature is particularly beneficial for homeowners who desire customized ventilation solutions.

On the other hand, the FV-05-11VK1 model also incorporates a similar motor and airflow options while emphasizing enhanced energy efficiency. With a quiet operating noise of only 0.3 sones at its low speed, it is one of the quietest fans in its class. This is critical for spaces like bathrooms where silence is often preferred. Additionally, the FV-05-11VK1 is equipped with a built-in damper system that helps prevent backdraft airflow, ensuring that conditioned air remains inside the home while outside air is effectively vented.

Lastly, the FV-11-15VK1 model showcases Panasonic's dedication to performance with its 150 CFM airflow capacity, making it suitable for larger rooms and higher moisture environments. This model retains the low noise level characteristic of its siblings, operating at 0.4 sones at low speed. It's an ideal choice for larger bathrooms or laundry rooms where increased ventilation is necessary to combat excessive humidity.

Across all three models, Panasonic employs its renowned ECM motor technology, which provides quicker and quieter operation while also ensuring the fans meet Energy Star standards. This commitment to energy efficiency not only saves utility costs but also reduces the carbon footprint of the household.

In summary, the Panasonic FV-05-11VKS1, FV-05-11VK1, and FV-11-15VK1 exhaust fans are designed with user-friendly features, advanced technologies, and superior characteristics that enhance indoor air quality while ensuring a quiet, efficient operation. Whether you are considering a replacement for an old fan or a new installation, Panasonic’s offerings are an excellent investment for maintaining a healthy home environment.