Panasonic KX-TDA100 installation manual Connecting to a Master DPT

Page 149

2.7.3 Digital EXtra Device Port (Digital XDP) Connection

Connecting to a Master DPT

To DLC8/DLC16 card

To DHLC8 card

(for connection of SLT)

4-conductor wiring cord Connect pins "T", "R", "D1" and "D2".

Master DPT

2-conductor wiring cord Connect pins "T" and "R".

Back View of DPTs

To DLC8/DLC16 card

To DHLC8 card

(for connection of SLT)

To slave DPT

Cable

Maximum Distance

ø0.4 mm: 30 m

ø0.5 mm: 50 m

ø 0.6 mm:

60 m

To SLT

CAT 5:

50 m

 

4-conductor wiring cord Connect pins "D1" and "D2".

Slave DPT

SLT

TO MAIN UNIT / PABX

TO DIGITAL

TO TEL

Installation Manual

149

Image 149
Contents Model No. KX-TDA100 Hybrid IP-PBXCategory Model No Shelves System Components TableMain Processing Card MPR Option Card Trunk CardsCategory Model No Extension Cards Power Supply UnitsOther Cards Optional SD MemoryIncompatible Panasonic Proprietary Telephones Equipment CompatibilityCompatible Panasonic Proprietary Telephones List of Abbreviations Safety NoticesImportant Safety Instructions For the PBX For All Telephone EquipmentDect Cell Station GHz Cell Station Only for KX-TDA0151CNRequirements What is User Information?Dect 6.0 Cell Station For the PBX This appliance must be earthed For users in the United KingdomFor users in Germany only For users in the European Union onlyFor users in New Zealand only For business users in the European UnionFor users in Taiwan only For users in Australia onlyAbout the Other Manuals Structure of this ManualAbout the software version of your PBX TrademarksTable of Contents Connection of Extensions 138 Information about the Other Cards 124Connection of Dect Portable Stations 151 Connection of 2.4 GHz Portable Stations 182249 245252 253Table of Contents Section System Outline System Highlights System HighlightsPC Phone/PC Console Features Portable Station PS FeaturesHospitality Features Built-in Simplified Voice Message SVM FeaturesConstruction of the Basic Shelf Basic System ConstructionBasic Shelf PBX System Connection DiagramMountable Equipment Model Name Optional EquipmentOptional Equipment Model No KX-TDA0290CE/ KX-TDA0290CJ General Description SpecificationsKX-TDA100 KX-TDA200 Dimension Weight when fully mountedCharacteristics System Capacity Maximum Optional Service CardsCards Installed in the Slots of the PBX Trunk Card Total 6*1 Total 8*2 Extension Card Total Mounted on Cards Mounted on Other Optional Service CardsMaximum Terminal Equipment MEC Card Calculation MEC Card CalculationCalculation Example KX-TDA100 Equipment Type MEC FigurePSU Capacity Power Supply Unit SelectionLoad Figure Calculation Calculation Example KX-TDA200 Section Installation Before Installation Before InstallationSafety Installation Instructions Installation PrecautionsBefore Installation Unpacking Installation of the PBXInside View Names and LocationsOpening the Front Cover Opening/Closing the Front CoverClosing the Front Cover Accessories and User-supplied Items Installing/Replacing the Power Supply UnitSafety Instructions FunctionInstalling the Power Supply Unit Replacing the Power Supply Unit Replace the PSU Frame Earth Connection Backup Power Supply Duration Backup Battery ConnectionConnecting Backup Batteries User-supplied ItemsBattery Switch Battery Connector Installing Optional Service Cards Installing/Removing the Optional Service CardsInstalling/Removing the Optional Service Cards Covering the Blank Slots Handling of the Cables Removing the Optional Service Cards Connector Type Pin Number Used for Types of ConnectorsUSB MPR For T1/E1/PRI/IP-GW16/IP-EXT16 Cards Attaching to an RJ45 ConnectorAttaching a Ferrite Core For a BRI Card For Extension Cards Attaching to an Amphenol ConnectorFastening Amphenol Connector DID8 DHLC8 DLC8 DLC16 Amphenol Connector Pin Assignment ChartWall Mounting KX-TDA200 Wall Mounting KX-TDA200 Wall Wall Mounting KX-TDA100Wall Mounting KX-TDA100 Floor Standing KX-TDA200 Only TOP Front Overview Surge Protector InstallationInstallation Installation of an Earth Rod Outside InstallationSurge Protector Installation MPR Card Information about the Main Processing CardColour LED IndicationsIndication MEC Card KX-TDA0105 RMT Card KX-TDA0196 Information about the Trunk Cards Signal Name Function Amphenol ConnectorSignal Name Pin Assignments2 DID8 Card KX-TDA0182 LED Indications Switch Switch Settings on LCOT8/LCOT16 cards3 CID/PAY8 Card KX-TDA0189 Type4 CID8 Card KX-TDA0193 5 E&M8 Card KX-TDA0184 T1C T1D T1E T1F T1G T1H 6 T1 Card KX-TDA0187 Switch SettingsSwitch Type Level Function RJ45 Connector for Trunk UseRJ45 Connector for Extension Use Maximum Cabling Distance of Extension Connection 7 E1 Card KX-TDA0188 Signal Name Level Function BNC coaxial Connector TXBNC coaxial Connector RX 8 BRI4 Card KX-TDA0284 and BRI8 Card KX-TDA0288 TX1 RX2 RX1 TX2 Layer Line LED PatternMaster Clock LED PatternMaximum Cabling Distance of S0 Bus Connection 9 PRI30 Card KX-TDA0290CE/KX-TDA0290CJ Termination Card Status SYNC-ERR RAI AIS Sync Link 10 PRI23 Card KX-TDA0290 100 Installation Manual Sync Link Input I/Output O Function RJ45 Connector 10BASE-TIP-GW4 Card KX-TDA0480 Card Status Online Alarm IAM Busy Link Data COL Siosel IP-GW4E Card KX-TDA0484 RJ45 Connector 10BASE-T/100BASE-TXCard Status Online Alarm IP-GW16 Card KX-TDA0490 Installation Manual 107 CSIF4 Card KX-TDA0143 and CSIF8 Card KX-TDA0144 Information about the Extension CardsRJ45 Connector D1B DHLC8 Card KX-TDA0170D1C 3 DLC8 Card KX-TDA0171 D2C 4 DLC16 Card KX-TDA0172 Installation Manual 115 5 SLC8 Card KX-TDA0173 Indication Colour EXT-CID Card KX-TDA0168 Installation Manual 119 120 Installation Manual Installation Manual 121 IP-EXT16 Card KX-TDA0470 Installation Manual 123 1 OPB3 Card KX-TDA0190 Information about the Other Cards2 DPH4 Card KX-TDA0161 User-supplied not included Copper wirePin Terminal Block 3 DPH2 Card KX-TDA0162 Standard Signal Name Proprietary Signal NamePath Doorphone Call Path 4 EIO4 Card KX-TDA0164 C4b C4a C3b C3a C2b C2a C1b C1a External Relay Connection DiagramExternal Sensor ECHO16 Card KX-TDA0166 6 MSG4 Card KX-TDA0191 ESVM2 Card KX-TDA0192 and ESVM4 Card KX-TDA0194 CTI-LINK Card KX-TDA0410 Card Status Link Status DSS Console Connection of ExtensionsPT-interface CS Indicates that the extension card supports the terminal With DPT Parallel Connection of the ExtensionsWith APT With KX-DT300 Series DPT except KX-DT321 Using a Modular T-AdaptorUsing an EXtra Device Port With Other DPT except KX-T7560 and KX-T7565 With KX-T7600 Series DPT except KX-T7665Back View of DPTs Digital EXtra Device Port Digital XDP ConnectionWith KX-DT300 Series DPT To Main Unit To TEL Pabx To Main Unit Pabx With KX-T7600 Series DPT except KX-T7600E Series146 Installation Manual With KX-T7600E Series DPT Connecting to a Slave DPT Connecting to a Master DPT KX-T7633/KX-T7636 First Party Call Control CTI ConnectionKX-DT343/KX-DT346 Connection of Dect Portable Stations RF SpecificationOverview Required Equipment and Maximum Number of CallsNumber of Carriers Frequency BandCarrier Spacing Bit RateInvestigate the installation site Procedure OverviewPrepare for site survey Conduct the site surveyMount the CS on the wall Finish the site surveyConnect the CS and PS to the PBX and test the operation Understanding Radio Waves Characteristics of Radio WavesSite Planning Transmission Tendency Object MaterialSite Survey Preparation Radio Signal Strength LevelsCS Coverage Area Things to take note Example Installing in a Room Separated by Interior WallsCS installation plan Before Site Survey Using the KX-TCA255/KX-TCA256/KX-TCA355Checking the CS ID Number Assigning the CS ID Number to the PSUsing the KX-TD7590 DIP Switch Setting and Installing the CS Temporarily for Site SurveyOFF on KX-TDA0158CEKX-TDA0141CE/KX-TDA0142CE To survey other slots Testing the Radio Signal StrengthPS CH0 Log No Referring to the Stored Scan DataClearing the Stored Scan Data After Site Survey Using a Csif Card Connecting a Cell Station to the PBXAccessories and User-supplied Items for the CS User-supplied not included RJ11 connectorUsing a DHLC/DLC Card KX-TDA0141CE For the KX-TDA0142CE User only Connecting the CSInstallation Manual 173 Using the KX-TCA155/KX-TCA255/KX-TCA256/KX-TCA355 Entering the PBX System Programming Mode Using a PTRegistering the PS PS RegistrationSystem Lock Password /OK Using the KX-TD7580System Lock Password Using the KX-TCA155/KX-TCA255/KX-TCA256/KX-TCA355 Setting the PIN for PBXUsing the KX-TD7580 Changing the Display Language of the PSHandset PIN Testing the OperationIf the registration information is still stored in the PS Mounting the KX-TDA0158CE Wall MountingReference for Wall Mounting KX-TDA0158CE Install a screw here 83 mmMounting the KX-TDA0141CE/KX-TDA0142CE Reference for Wall Mounting KX-TDA0141CE/KX-TDA0142CE Install a screw here 71 mmConnection of 2.4 GHz Portable Stations Installation Manual 183 Using the KX-TD7680 Using the KX-TD7684/KX-TD7694Using the KX-TD7690 Prepare the CS for site surveyInstallation Manual 185 Object Installation Manual 187 188 Installation Manual KX-TDA0151CN 100 m KX-TDA0151CN 50 m Installation Manual 189 KX-TDA0151/KX-TDA0152 OFFKX-TDA0141/KX-TDA0142 KX-TDA0151/KX-TDA0152KX-TDA0141/KX-TDA0142 Scan Data No CS No Site SurveyPS CS NO.1 LEVEL12 Scan Data No Scan Data No Deleting the Stored Scan DataKX-TDA0151/KX-TDA0152 KX-TDA0141/KX-TDA0142 KX-TDA0152/KX-TDA0142 KX-TDA0151/KX-TDA0141 200 Installation Manual Entering the System Programming Mode Using the KX-TD7684/KX-TD7694 When the PS has not been registered yetUsing the KX-TD7680 Using the KX-TD7690Setting the System Lock 692 Setting the PIN for PS Using the KX-TD7684/KX-TD7694System Mounting the KX-TDA0151/KX-TDA0152 Installation Manual 207 Reference for Wall Mounting KX-TDA0151/KX-TDA0152 Mounting the KX-TDA0141/KX-TDA0142 Reference for Wall Mounting KX-TDA0141/KX-TDA0142 Names and Locations of CS Connection of Dect 6.0 Portable StationsNumber of Carriers Carrier Spacing Radio Access MethodUsing the KX-TD7685/KX-TD7695 214 Installation Manual Installation Manual 215 216 Installation Manual Installation Manual 217 218 Installation Manual Using the KX-TD7685/KX-TD7695 KX-TDA0155 KX-TDA0158 KX-TDA0155 KX-TDA0158 Installation Manual 223 224 Installation Manual PS CH0 L12 226 Installation Manual Installation Manual 227 KX-TDA0155KX-TDA0158 Installation Manual 229 D1B D1A Connect the cable from the PBX to the CS Setting the PIN for PS PIN for PS Registration If Rejected or Time out is displayed 691Mounting the KX-TDA0155/KX-TDA0158 236 Installation Manual Reference for Wall Mounting Install a screw here 100 mm 83 mmMaximum Cabling Distance Installing the Doorphone KX-T30865/KX-T7765Installation Manual 239 Connection Connection of Peripherals Connection of PeripheralsPager Connection ChartsPC/Printer via RS-232C Pin AssignmentsRS-232C Signals For connecting a printer/PC with a 25-pin RS-232C connectorPC/CTI Server via USB version Power Failure Connections Power Failure ConnectionsUsing Analogue Trunk Card and Extension Card RJ11 Connector Pin Assignments for Analogue Trunk CardPFT Ports 1 Signal Name Function RJ11 Connector Pin Assignments for Extension CardPFT Ports 3 and 4 for LCOT16 card only Signal Name Function RJ45 Connector Line 1 Pin Assignments Using BRI CardSwitch Settings RJ45 Connector Line 2 Pin Assignments Starting the PBX System Initialisation ProcedureStarting the PBX Confirming the Trunk Connection Guide for the Maintenance Console Overview PC Connection PC ConnectionSerial Interface Connection LAN Connection via CTI-LINK CardRD RXD SD TXD ER DTR DR DSR External Modem ConnectionInstalling and Starting the Maintenance Console Installation of the Maintenance ConsolePassword Security System RequirementsPage Select KX-TDA100/200 from PBX Model When country/area data do not match258 Installation Manual Section Troubleshooting Installation TroubleshootingConnection Cause SolutionTrunk is connected to the T2/R1 Operation 264 Installation Manual Installation Manual 265 Operation Using the Reset ButtonDescription Troubleshooting by Error LogError Log Display Format Sub Code Error Message Log Information Appendix Revision History Changed ContentsPmpr Software File Version New OptionsInstallation Manual 271 272 Installation Manual Installation Manual 273 New Contents Index Numerics KX-TDA0173 8-Port Single Line Telephone Extension PSU Reference for Wall Mounting Page Installation Manual 281 For Future Reference
Related manuals
Manual 194 pages 61.97 Kb Manual 248 pages 58.62 Kb Manual 40 pages 36.33 Kb Manual 58 pages 2.3 Kb Manual 194 pages 61.15 Kb

KX-TDA100 specifications

The Panasonic KX-TDA100 is a versatile digital hybrid telephone system designed to meet the communication needs of small to medium-sized businesses. This system blends traditional telephone functions with advanced digital technology, making it an excellent choice for organizations looking to enhance their telecommunications infrastructure.

One of the key features of the KX-TDA100 is its ability to support both digital and analog telephony, allowing businesses to integrate existing telephone lines and devices with newer technologies. The system can accommodate up to 100 extensions, making it scalable and suitable for growing businesses. Additionally, it supports a variety of communication services, including voice mail, computer telephony integration, and automatic call distribution, which enhances customer service capabilities.

The KX-TDA100 utilizes advanced digital signal processing technology, ensuring clear and reliable communication. It employs features such as call forwarding, caller ID, call waiting, and conference calling, which improve productivity and streamline communication among team members. The system also allows for the integration of mobile devices through its support for SIP trunking, enabling seamless communication even when employees are on the go.

Furthermore, the KX-TDA100 includes built-in voicemail functionality, allowing businesses to manage messages efficiently. The voicemail system supports features like voicemail-to-email, which provides users with immediate access to their messages, and the option to customize greetings and auto-attendants that enhance caller experiences.

Security is another critical aspect of the KX-TDA100. The system offers various security features to protect against unauthorized access and ensure data integrity, including encryption and secure network protocols. This attention to security makes it suitable for businesses that handle sensitive information.

Overall, the Panasonic KX-TDA100 combines flexibility, scalability, and advanced technology, making it an ideal solution for businesses looking to improve their communication systems. Its user-friendly design, robust feature set, and ability to grow with the organization make it a reliable choice for enhancing productivity and ensuring effective communication within teams and with customers. Whether deploying for day-to-day operations or accommodating remote work, the KX-TDA100 offers the reliability and features that modern businesses require.